Mitigation Strategy for Duck Curve in High Photovoltaic Penetration Power System Using Concentrating Solar Power Station
Qi Wang,
Ping Chang,
Runqing Bai,
Wenfei Liu,
Jianfeng Dai and
Yi Tang
Additional contact information
Qi Wang: School of Electrical Engineering, Southeast University, Nanjing 210096, China
Ping Chang: School of Electrical Engineering, Southeast University, Nanjing 210096, China
Runqing Bai: Electric Power Research Institute, State Grid Gansu Electric Power Company, Lanzhou 730070, China
Wenfei Liu: Electric Power Research Institute, State Grid Gansu Electric Power Company, Lanzhou 730070, China
Jianfeng Dai: School of Electrical Engineering, Southeast University, Nanjing 210096, China
Yi Tang: School of Electrical Engineering, Southeast University, Nanjing 210096, China
Energies, 2019, vol. 12, issue 18, 1-16
Abstract:
Concentrating solar power (CSP) station is counted as a promising flexible power supply when the net load power curve is duck-shaped in high photovoltaic (PV) penetration power system, which may lead to the serious phenomenon of PV curtailment and a large-capacity power shortage. This paper presents a mitigation strategy that replaces thermal power station with CSP station to participate in the optimal operation of power system for solving the duck-shaped net load power curve problem. The proposed strategy utilizes the dispatchability of thermal storage system (TSS) and the fast output regulation of unit in the CSP station. Simultaneously, considering the operation constraints of CSP station and network security constraints of the system, an optimization model is developed to minimize the overall cost including operation and penalty. The results obtained by nonlinear optimization function demonstrate that the replacement of concentrating solar power (CSP) station contributes to reducing the PV curtailment and lost load, while increasing the available equivalent slope for power balance. Thus, the proposed mitigation strategy can promote the penetration of PV generation and improve the flexibility of power system.
Keywords: duck curve; photovoltaic (PV) penetration; concentrating solar power (CSP) station; operation mode; regulation capability (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2019
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (9)
Downloads: (external link)
https://www.mdpi.com/1996-1073/12/18/3521/pdf (application/pdf)
https://www.mdpi.com/1996-1073/12/18/3521/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:12:y:2019:i:18:p:3521-:d:266874
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().