Effect of Saturated Steam Carried Downward on the Flow Properties in the Downcomer of Steam Generator
Yan Liu,
Hui-lie Shi,
Chun Gui,
Xian-yuan Wang and
Rui-feng Tian
Additional contact information
Yan Liu: Fundamental Science on Nuclear Safety and Simulation Technology Laboratory, Harbin Engineering University, Harbin 150001, China
Hui-lie Shi: Research Institute of Nuclear Power Operation, Wuhan 430223, China
Chun Gui: Research Institute of Nuclear Power Operation, Wuhan 430223, China
Xian-yuan Wang: Fundamental Science on Nuclear Safety and Simulation Technology Laboratory, Harbin Engineering University, Harbin 150001, China
Rui-feng Tian: Research Institute of Nuclear Power Operation, Wuhan 430223, China
Energies, 2019, vol. 12, issue 19, 1-24
Abstract:
The saturated water separated by the steam separator in a natural circulation steam generator may carry a small amount of saturated steam into the downcomer. The steam contacts subcooled water and condenses directly in the downcomer causing the variations in the pressure and steam quality and likely affecting the stability of the water cycle in the secondary loop. It is not conducive to core heat extraction and thus affects nuclear safety. The mathematical model of the downcomer was established in this study based on the internal structures of a natural circulation steam generator. The volume-of-fluid (VOF) and large-eddy-simulation (LES) models were used for analysis on FLUENT software (ANSYS, Pittsburgh, PA. USA) platform. The influence of direct contact condensation of top-down flowing steam on the flow properties in the downcomer of the steam generator under high pressure was studied. The trend of the temperature, pressure, and the void fraction were obtained by combining these models with the condensation model. Further, a one-dimensional calculation program based on the differential drop was also developed to assess the flow field in the downcomer. The calculation results are in good agreement with the experimental results which indicated that, when affected by the saturated steam carried downward, the flow temperature close to the exit of the downcomer rises slightly due to the absorption of the heat released by the steam condensation. Furthermore, the density corrected by the pressure-drop is more reliable than that corrected by the temperature. After the velocity in the downcomer has increased to a certain value, the sensitivity of steam quality to the subcooling degree in the downcomer begins to decline. The results in this paper can be used to perform stability analyses and to design steam generators. The results of research are helpful to the stability analysis and the design of a steam generator, and to improve the accuracy of the measurement of the steam generator operating parameters, thus enhancing the safety of Pressurize Water Reactor operating system.
Keywords: direct contact and condensation of steam; natural circulation steam generator; downcomer; condensation model (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2019
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/12/19/3650/pdf (application/pdf)
https://www.mdpi.com/1996-1073/12/19/3650/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:12:y:2019:i:19:p:3650-:d:270285
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().