Improvement of Heat Dissipation Characteristics of Cu Bus-Bar in the Switchboards through Shape Modification and Surface Treatment

Min-Jun Kim, Sang-Hwan Bak, Woo-Chul Jung, Deog-Jae Hur, Dong-Shin Ko and Man-Sik Kong
Additional contact information
Min-Jun Kim: Advanced Materials & Processing Center, Institute for Advanced Engineering (IAE), Yongin 175-28, Korea
Sang-Hwan Bak: Advanced Materials & Processing Center, Institute for Advanced Engineering (IAE), Yongin 175-28, Korea
Woo-Chul Jung: Advanced Materials & Processing Center, Institute for Advanced Engineering (IAE), Yongin 175-28, Korea
Deog-Jae Hur: Research & Business Cooperation Center, Institute for Advanced Engineering (IAE), Yongin 175-28, Korea
Dong-Shin Ko: Research & Business Cooperation Center, Institute for Advanced Engineering (IAE), Yongin 175-28, Korea
Man-Sik Kong: Advanced Materials & Processing Center, Institute for Advanced Engineering (IAE), Yongin 175-28, Korea

Energies, 2019, vol. 12, issue 1, 1-11

Abstract: In order to improve energy efficiency by increasing heat dissipation performance of bus-bar which distributes the current in high-power switchboard, the heat dissipation effects of the shape modification and surface treatment of Cu bus-bar were studied. The surface temperatures of the conventional plate-type bus-bar, and the improved tunnel-type bus-bar were compared by using electromagnetic and thermal analyses. The optimum thickness of tunnel-type bus-bar and the spacing and array among three bus-bars were calculated; and the surface temperature of tunnel-type bus-bar showed 7.9 °C lower than that of plate-type bus-bar in a 3-phase array condition. In addition, the surface and internal temperatures of the uncoated, CNT (Carbon nanotube)-coated, and BN (Boron nitride)-coated Cu bus-bars were measured with thermal imaging camera and the experiment using a hot plate. It was confirmed that the difference in the internal temperature between uncoated and BN-coated Cu was 19.4 °C. The application of the bus-bar improved from this study might contribute to the increase in power energy efficiency.

Keywords: switchboard system; Cu bus-bar; heat dissipation; electromagnetic thermal analysis; boron nitride coating (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2019
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/1996-1073/12/1/146/pdf (application/pdf)
https://www.mdpi.com/1996-1073/12/1/146/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:12:y:2019:i:1:p:146-:d:194421

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:12:y:2019:i:1:p:146-:d:194421