EconPapers    
Economics at your fingertips  
 

Load Capacity Analysis of Self-Excited Induction Generators Based on Routh Criterion

Jia Li, Xinzhen Wu, Xibo Yuan and Haifeng Wang
Additional contact information
Jia Li: College of Electrical Engineering, Qingdao University, Qingdao 266071, China
Xinzhen Wu: College of Electrical Engineering, Qingdao University, Qingdao 266071, China
Xibo Yuan: College of Electrical Engineering, Qingdao University, Qingdao 266071, China
Haifeng Wang: College of Electrical Engineering, Qingdao University, Qingdao 266071, China

Energies, 2019, vol. 12, issue 20, 1-16

Abstract: In this paper, the Routh criterion has been used to analyze the stability of a self-excited induction generator-based isolated system which is regarded as an autonomous system. Special focus has been given to the load capacity of the self-excited induction generator. The state matrix of self-excited induction generators with resistor-inductor load has been established based on transient equivalent circuits in the stator stationary reference-frame. The recursive Routh table of self-excited induction generators is established by the characteristic polynomial coefficients of the state matrix. According to the Routh stability criterion, the necessary and sufficient condition to predict the critical loads of self-excited induction generators is deduced, from which the critical load impedance can be calculated. A simple self-excited induction generator-based isolated power system has been built up with a 2.2 kW self-excited induction generator. The theoretical analysis and experiments were all carried out based on this platform. In the range determined by the minimum excitation capacitance ( C min ) and the maximum excitation capacitance ( C max ), the critical loads under various power factors have been calculated. The agreement of the calculated theoretical results and experimental results demonstrate the effectiveness and accuracy of the proposed analysis method. The conclusions achieved lay a foundation for further application of Routh stability criterion in self-excited induction generator-based power systems analysis.

Keywords: self-excited induction generator; Autonomous system; Routh criterion; Stability; Load Capacity (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2019
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/12/20/3953/pdf (application/pdf)
https://www.mdpi.com/1996-1073/12/20/3953/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:12:y:2019:i:20:p:3953-:d:277641

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:12:y:2019:i:20:p:3953-:d:277641