Study of the Influence of Ventilation Pipeline Setting on Cooling Effects in High-Temperature Mines
Zhiyong Zhou,
Yimeng Cui,
Long Tian,
Jianhong Chen,
Wei Pan,
Shan Yang and
Pei Hu
Additional contact information
Zhiyong Zhou: School of Resources and Safety Engineering, Central South University, Changsha 410083, China
Yimeng Cui: School of Resources and Safety Engineering, Central South University, Changsha 410083, China
Long Tian: School of Resources and Safety Engineering, Central South University, Changsha 410083, China
Jianhong Chen: School of Resources and Safety Engineering, Central South University, Changsha 410083, China
Wei Pan: School of Resources and Safety Engineering, Central South University, Changsha 410083, China
Shan Yang: School of Resources and Safety Engineering, Central South University, Changsha 410083, China
Pei Hu: School of Resources and Safety Engineering, Central South University, Changsha 410083, China
Energies, 2019, vol. 12, issue 21, 1-16
Abstract:
The high-temperature environment is a major factor that affects deep mining. Cooling has become a major expense, accounting for up to 25% of the total energy consumption of such mines. To address methods of cooling and the cooling cost, this paper studies the influence of the ventilation duct layout on the cooling effect. Six models were created in ICEM-CFD (3D modeling software), and the influence of cold airflow diffusion on the temperature of the mine environment was numerically simulated using ANSYS Fluent. Under the condition of the same ventilation volume, two models utilizing single pipe and double pipe scenarios were established, and six points were selected as the pipeline suspension position, forming six ventilation duct models. The cooling effect of each model was evaluated by analyzing the average temperature of the roadway section, the three-dimensional distribution of the roadway temperature and the velocity streamline of the whole roadway. The results show that the double-tube model has greater advantages than the single-tube model does, due to its superior local temperature, average temperature of the cross-section, range below 303 K, temperature uniformity and local wind speed. Among the models, model 4 (diameter of 0.5 m, 1.9 m away from the bottom of the roadway and 2.4 m away from the center of the circle) is the best pipeline layout scheme for comprehensive temperature values, roadway temperature uniformity and other factors. The average temperature is 299.3 K within 8 m from the mining face, which is 1.66 K lower than that of the single tube model. This configuration will increase the comfort of the mining environment and reduce cooling costs. These results can provide a reference for ventilation duct layouts of roadways in high temperature mines.
Keywords: mine ventilation; ventilation duct setting; mine cooling; numerical simulation (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2019
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (4)
Downloads: (external link)
https://www.mdpi.com/1996-1073/12/21/4074/pdf (application/pdf)
https://www.mdpi.com/1996-1073/12/21/4074/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:12:y:2019:i:21:p:4074-:d:280295
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().