Novel Grounding Electrode Model with Axial Construction Space Consideration
Yihua Dan,
Zhanlong Zhang,
Yiqiao Li,
Jun Deng and
Jing Zou
Additional contact information
Yihua Dan: State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing 400030, China
Zhanlong Zhang: State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing 400030, China
Yiqiao Li: State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing 400030, China
Jun Deng: Maintenance & Test Centre, EHV, China Southern Power Grid, Guangzhou 510663, China
Jing Zou: State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing 400030, China
Energies, 2019, vol. 12, issue 24, 1-17
Abstract:
Grounding electrodes are used to ensure safe operation of electrical apparatus. The limited axial construction space for grounding electrodes is a significant constraining factor. Grounding performance will attenuate rapidly under the influence of the reduced length of horizontal or vertical grounding electrodes. However, if additional resistance-reducing measures are adopted, the operation and maintenance cost of grounding electrodes will considerably increase. To solve above problem, this study proposed a novel grounding model that uses a helical grounding electrode to improve grounding performance within limited axial construction space. Firstly, a calculation model of finite element methods (FEM) is built based on the concept of increasing the contact area between the grounding electrodes and the soil. Grounding performance parameters of helical grounding electrodes, grounding resistance, electrical potential rise (EPR) distribution and maximum touch voltage, are analyzed. At the same time, structural parameters and buried depth for the helical grounding electrodes are studied and the optimal design criteria for the parameters are given. Results show that the helical grounding electrode exhibits better grounding performance in a limited axial construction area.
Keywords: grounding; finite element methods; electric potential (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2019
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/12/24/4765/pdf (application/pdf)
https://www.mdpi.com/1996-1073/12/24/4765/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:12:y:2019:i:24:p:4765-:d:297739
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().