Daylighting Performance of Solar Control Films for Hospital Buildings in a Mediterranean Climate
Carmen María Calama-González,
Ángel Luis León-Rodríguez and
Rafael Suárez
Additional contact information
Carmen María Calama-González: Instituto Universitario de Arquitectura y Ciencias de la Construcción, Escuela Técnica Superior de Arquitectura, Universidad de Sevilla, Av. Reina Mercedes 2, 41012 Seville, Spain
Ángel Luis León-Rodríguez: Instituto Universitario de Arquitectura y Ciencias de la Construcción, Escuela Técnica Superior de Arquitectura, Universidad de Sevilla, Av. Reina Mercedes 2, 41012 Seville, Spain
Rafael Suárez: Instituto Universitario de Arquitectura y Ciencias de la Construcción, Escuela Técnica Superior de Arquitectura, Universidad de Sevilla, Av. Reina Mercedes 2, 41012 Seville, Spain
Energies, 2019, vol. 12, issue 3, 1-19
Abstract:
One of the main retrofitting strategies in warm climates is the reduction of the effects of solar radiation. Cooling loads, and in turn, cooling consumption, can be reduced through the implementation of reflective materials such as solar control films. However, these devices may also negatively affect daylight illuminance conditions and the electric consumption of artificial lighting systems. In a hospital building, it is crucial to meet daylighting requirements as well as indoor illuminance levels and visibility from the inside, as these have a significant impact on health outcomes. The aim of this paper is to evaluate the influence on natural illuminance conditions of a solar control film installed on the windows of a public hospital building in a Mediterranean climate. To this end, a hospital room, with and without solar film, was monitored for a whole year. A descriptive statistical analysis was conducted on the use of artificial lighting, illuminance levels and rolling shutter aperture levels, as well as an analysis of natural illuminance and electric consumption of the artificial lighting system. The addition of a solar control film to the external surface of the window, in combination with the user-controlled rolling shutter aperture levels, has reduced the electric consumption of the artificial lighting system by 12.2%. Likewise, the solar control film has increased the percentage of annual hours with natural illuminance levels by 100–300 lux.
Keywords: hospital building retrofitting; solar control films; daylighting performance; solar radiation; illuminance; energy consumption; energy savings (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2019
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/12/3/489/pdf (application/pdf)
https://www.mdpi.com/1996-1073/12/3/489/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:12:y:2019:i:3:p:489-:d:203317
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().