Thermal Comfort Evaluation of Rooms Installed with STPV Windows
Hao Tian,
Wei Zhang,
Lingzhi Xie,
Zhichun Ni,
Qingzhu Wei,
Xinwen Wu,
Wei Wang and
Mo Chen
Additional contact information
Hao Tian: Key Laboratory of Deep Underground Science and Engineering (Ministry of Education), School of Architecture and Environment, Sichuan University, Chengdu 610065, China
Wei Zhang: Key Laboratory of Deep Underground Science and Engineering (Ministry of Education), School of Architecture and Environment, Sichuan University, Chengdu 610065, China
Lingzhi Xie: Institute of New Energy and Low-carbon Technology, Sichuan University, Chengdu 610065, China
Zhichun Ni: Suzhou Talesun Solar Technologies Co., Ltd., Suzhou 215542, China
Qingzhu Wei: Suzhou Talesun Solar Technologies Co., Ltd., Suzhou 215542, China
Xinwen Wu: Key Laboratory of Deep Underground Science and Engineering (Ministry of Education), School of Architecture and Environment, Sichuan University, Chengdu 610065, China
Wei Wang: Key Laboratory of Deep Underground Science and Engineering (Ministry of Education), School of Architecture and Environment, Sichuan University, Chengdu 610065, China
Mo Chen: Key Laboratory of Deep Underground Science and Engineering (Ministry of Education), School of Architecture and Environment, Sichuan University, Chengdu 610065, China
Energies, 2019, vol. 12, issue 5, 1-15
Abstract:
Thermal comfort is an important aspect to take into consideration for the indoor environment of a building integrated with a semi-transparent Photovoltaics (STPV) system. The thermal comfort of units with photovoltaic windows and that of conventional windows, which is an ordinary without PV, were evaluated via on-site tests and questionnaires. Using the thermal comfort investigation of the test rig, the maximum difference in air temperature was found to be around 5 °C between test unit and comparison unit. The predicted mean vote (PMV)–predicted percentage dissatisfied (PPD) value of the test unit was better than that of the comparison unit. It was observed that on sunny days, the PMV value ranged from 0.2 (nature) to 1.3 (slightly warm) in the test unit, and that of the comparison unit was 0.7 (slightly warm) to 2.0 (warm), thereby providing better thermal comfort, especially during mornings. The maximum difference in PPD values was found to reach 27% between the two units at noon. On cloudy days, the difference was negligible, and the thermal sensation between the foot and the head were almost the same. Fifty respondents were asked to complete a carefully designed questionnaire. The thermal sensation of the test unit was better than that of comparison unit, which corresponded with the test results. Thermal, lighting, acoustic, and other environment comfort scores were combined, and the acceptance of the test unit with the STPV windows was found to be 73.8%. The thermal sensation difference between men and women was around 5%. Thus, during summer, STPV windows can improve the thermal comfort and potentially reduce the air-conditioning load.
Keywords: Semi-transparent PV (STPV) windows; thermal comfort; on-site test; questionnaire; PMV-PPD (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2019
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (2)
Downloads: (external link)
https://www.mdpi.com/1996-1073/12/5/808/pdf (application/pdf)
https://www.mdpi.com/1996-1073/12/5/808/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:12:y:2019:i:5:p:808-:d:209878
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().