EconPapers    
Economics at your fingertips  
 

Coordinated Control for Operating Characteristics Improvement of UHVDC Transmission Systems under Hierarchical Connection Scheme with STATCOM

Atiq Ur Rehman, Chunyi Guo and Chengyong Zhao
Additional contact information
Atiq Ur Rehman: The State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing 102206, China
Chunyi Guo: The State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing 102206, China
Chengyong Zhao: The State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing 102206, China

Energies, 2019, vol. 12, issue 5, 1-15

Abstract: Ultra-high voltage direct current (UHVDC) systems under hierarchical connection schemes (HCSs) linked to AC grids with different voltage levels (500 and 1000 kV) have been a great concern for power utilities to transfer bulk power. They have some operating issues like cascaded commutation failures and longer fault recovery time under certain fault conditions. Since STATCOM has the ability to effectively regulate AC busbar voltages, thus it is considered in this paper to improve the operating characteristics of UHVDC-HCS systems. To further improve the operating characteristics, a coordinated control between an UHVDC-HCS system and STATCOM is presented. To validate the effectiveness of coordinated control, the comparison between different control modes such as reactive power control (Q-control) and voltage control (V-control) in the outer loop control of STATCOM are conducted in detail. Various indices like commutation failure immunity index (CFII) and commutation failure probability index (CFPI) are also comprehensively evaluated in order to investigate robustness of the adopted coordinated control. An UHVDC-HCS system with multiple STATCOMs on the inverter side (500 kV bus) is developed in PSCAD/EMTDC. The impact of coordinated control on commutation failure phenomena and fault recovery time during single and three phase AC faults is analyzed. The analysis shows that coordinated control with V-control mode of STATCOM exhibits better performance in enhancing the operating characteristics of UHVDC-HCS system by improving the CFII, effectively reducing the CFPI and fault recovery time under various AC faults.

Keywords: commutation failure; coordinated control; fault recovery time; hierarchical connection scheme (HCS); STATCOM; UHVDC system (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2019
References: View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/1996-1073/12/5/945/pdf (application/pdf)
https://www.mdpi.com/1996-1073/12/5/945/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:12:y:2019:i:5:p:945-:d:213079

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:12:y:2019:i:5:p:945-:d:213079