EconPapers    
Economics at your fingertips  
 

Correlation of Ventilative Cooling Potentials and Building Energy Savings in Various Climatic Zones

Haolia Rahman and Hwataik Han
Additional contact information
Haolia Rahman: Mechanical Engineering, Politeknik Negeri Jakarta, Depok 16425, Jawa Barat, Indonesia
Hwataik Han: Mechanical Engineering, Kookmin University, 77 Jeungneung-ro, Seongbuk-gu, Seoul 02707, Korea

Energies, 2019, vol. 12, issue 6, 1-10

Abstract: The introduction of cool outdoor air can help in reducing the energy consumption for cooling during summer. Ventilative cooling potentials (VCPs) have been defined in various ways in the literature to represent potential cooling hours in specified outdoor temperature ranges. However, the energy-saving potential of ventilative cooling can differ between buildings in the same climatic zone depending on the buildings’ thermal characteristics and system operations. In this study, new VCPs are introduced with an index of temperature shift based on adaptive thermal comfort. This index can be determined based on the balance temperature difference of the buildings, which is defined as the heat gain in the building divided by the thermal transmission and air exchange characteristics of the building envelope under quasi-steady state conditions. The proposed method was also compared with those reported in the literature, including a computer-based VCP tool. It is the objective of the present study to investigate the correlation between VCPs and actual energy savings via ventilative cooling. Simulations were conducted in an office building for a four-month period during summer to calculate the energy saved via ventilative cooling in comparison with that achieved with a mechanical cooling system. Eight cities representing four different climatic conditions were considered: tropical, dry, temperate, and continental. Our results revealed a strong correlation between the energy savings and the proposed VCPs in the case of a proper temperature shift estimation in all climatic zones. The computerized VCP tool also exhibited good correlation with the calculated energy savings and with the VCPs proposed herein.

Keywords: energy; building; ventilation; cooling; outdoor air (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2019
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/1996-1073/12/6/968/pdf (application/pdf)
https://www.mdpi.com/1996-1073/12/6/968/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:12:y:2019:i:6:p:968-:d:213423

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:12:y:2019:i:6:p:968-:d:213423