EconPapers    
Economics at your fingertips  
 

Investigation on the Performance of a Compact Three-Fluid Combined Membrane Contactor for Dehumidification in Electric Vehicles

Ehsan Afrasiabian, Oleg Iliev, Inga Shklyar, Stefano Lazzari and Federica Boero
Additional contact information
Ehsan Afrasiabian: Fraunhofer Institute for Industrial Mathematics ITWM, Fraunhofer-Platz 1, 67663 Kaiserslautern, Germany
Oleg Iliev: Fraunhofer Institute for Industrial Mathematics ITWM, Fraunhofer-Platz 1, 67663 Kaiserslautern, Germany
Inga Shklyar: Fraunhofer Institute for Industrial Mathematics ITWM, Fraunhofer-Platz 1, 67663 Kaiserslautern, Germany
Stefano Lazzari: Department of Architecture and Design (DAD), University of Genoa, 16123 Genoa, Italy
Federica Boero: Tecnologie Innovative per il Controllo e lo Sviluppo Sostenibile—TICASS S.c.r.l., 16121 Genoa, Italy

Energies, 2019, vol. 12, issue 9, 1-15

Abstract: In this paper, the performance of a compact Three-Fluid Combined Membrane Contactor (3F-CMC) is investigated using Computational Fluid Dynamics (CFD), supported and validated with a good agreement by an experimental campaign made on a fully working prototype. This internally-cooled membrane contactor is the core component of a hybrid air conditioning system for electric vehicles (EVs) developed in a successful H2020 project called XERIC. In the adopted numerical approach, the conjugate heat and mass transfer inside the 3F-CMC is described by non-isothermal incompressible flows and vapor transport through a PTFE hydrophobic membrane. The sensitivity of the 3F-CMC performance to air/desiccant flow rates, temperature, humidity, and desiccant concentration is analyzed numerically through the validated CFD codes. According to this study, the moisture removal increases by the inlet humidity ratio, nearly linearly. Under the considered conditions (where the inlet air temperature is 26.2 °C), when the inlet relative humidity (RH) is 75% the moisture removal is about 450% higher than the case RH = 37%, while the absorption effectiveness declines about 45%. Furthermore, this study shows that the amount of absorbed vapor flux rises by increasing the airflow rate; on the other hand, the higher the airflow rate, the lower is the overall absorption efficiency of the 3F-CMC. This investigation gives important suggestions on how to properly operate a 3F-CMC in order to achieve the requested performance, especially in hot and humid climates.

Keywords: electric vehicles; desiccant solution; membrane contactors; internal cooling; dehumidification; CFD (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2019
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/12/9/1660/pdf (application/pdf)
https://www.mdpi.com/1996-1073/12/9/1660/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:12:y:2019:i:9:p:1660-:d:227557

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:12:y:2019:i:9:p:1660-:d:227557