EconPapers    
Economics at your fingertips  
 

Performance Investigation of a Two-Bed Type Adsorption Chiller with Various Adsorbents

Jung-Gil Lee, Kyung Jin Bae and Oh Kyung Kwon
Additional contact information
Jung-Gil Lee: Thermal and Fluid System Group, Korea Institute of Industrial Technology, Cheonan-si, Chungcheongnam-do 31056, Korea
Kyung Jin Bae: Thermal and Fluid System Group, Korea Institute of Industrial Technology, Cheonan-si, Chungcheongnam-do 31056, Korea
Oh Kyung Kwon: Thermal and Fluid System Group, Korea Institute of Industrial Technology, Cheonan-si, Chungcheongnam-do 31056, Korea

Energies, 2020, vol. 13, issue 10, 1-16

Abstract: In this study, the performance evaluation of an adsorption chiller (AD) system with three different adsorbents—silica-gel, aluminum fumarate, and FAM-Z01—was conducted to investigate the effects of adsorption isotherms and physical properties on the system’s performance. In addition, the performance evaluation of the AD system for a low inlet hot-water temperature of 60 °C was performed to estimate the performance of the system when operated by low quality waste heat or sustainable energy sources. For the simulation work, a two-bed type AD system is considered, and silica-gel, metal organic frameworks (MOFs), and ferro-aluminophosphate (FAPO, FAM-Z01) were employed as adsorbents. The simulation results were well matched with the laboratory-scale experimental results and the maximum coefficient of performance (COP) difference was 7%. The cooling capacity and COP of the AD system were investigated at different operating conditions to discuss the influences of the adsorbents on the system performance. Through this study, the excellence of the adsorbent, which has an S-shaped isotherm graph, was presented. In addition, the influences of the physical properties of the adsorbent were also discussed with reference to the system performance. Among the three different adsorbents employed in the AD system, the FAM-Z01 shows the best performance at inlet hot water temperature of 60 °C, which can be obtained from waste heat or sustainable energy, where the cooling capacity and COP were 5.13 kW and 0.47, respectively.

Keywords: adsorption chiller; adsorbent; isotherm characteristics; coefficient of performance; cooling capacity; simulation; metal organic frameworks; low quality waste heat; sustainable energy (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2020
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (5)

Downloads: (external link)
https://www.mdpi.com/1996-1073/13/10/2553/pdf (application/pdf)
https://www.mdpi.com/1996-1073/13/10/2553/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:13:y:2020:i:10:p:2553-:d:359720

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:13:y:2020:i:10:p:2553-:d:359720