Energy Savings in an Office Building with High WWR Using Glazing Systems Combining Thermochromic and Electrochromic Layers
Michaela Detsi,
Aris Manolitsis,
Ioannis Atsonios,
Ioannis Mandilaras and
Maria Founti
Additional contact information
Michaela Detsi: Lab. of Heterogeneous Mixtures and Combustion Systems, School of Mechanical Engineering, National Technical University of Athens, Heroon Polytechniou 9, 15780 Zografou, Greece
Aris Manolitsis: Lab. of Heterogeneous Mixtures and Combustion Systems, School of Mechanical Engineering, National Technical University of Athens, Heroon Polytechniou 9, 15780 Zografou, Greece
Ioannis Atsonios: Lab. of Heterogeneous Mixtures and Combustion Systems, School of Mechanical Engineering, National Technical University of Athens, Heroon Polytechniou 9, 15780 Zografou, Greece
Ioannis Mandilaras: Lab. of Heterogeneous Mixtures and Combustion Systems, School of Mechanical Engineering, National Technical University of Athens, Heroon Polytechniou 9, 15780 Zografou, Greece
Maria Founti: Lab. of Heterogeneous Mixtures and Combustion Systems, School of Mechanical Engineering, National Technical University of Athens, Heroon Polytechniou 9, 15780 Zografou, Greece
Energies, 2020, vol. 13, issue 11, 1-18
Abstract:
This paper assesses energy savings in terms of heating, cooling, and artificial lighting achieved in an office building with a high Window to Wall Ratio (WWR), located in Athens and Stockholm. Six different configurations of triple pane windows combining thermochromic, electrochromic, and low-e coatings in Insulated Glass Units (IGUs) are examined to quantify the potential of increasing energy savings in office buildings. The combination of electrochromic and thermochromic layers on the outer pane of the triple IGU, achieved an 18.5% and 8.1% reduction in annual primary energy use for Athens and Stockholm, respectively. The used switching strategy ensured the visual comfort of the employees and provided adequate daylight in both cases. It was found that in Stockholm the cooling system can be downsized considerably, achieving important cost reduction in the HVAC system. The analysis also takes into account the reduction of thermal storage in the building envelope due to the switchable windows. This reduction is beneficial in the case of Athens, but it can reduce energy savings in Stockholm. Therefore, for colder climates, it is important to increase window heat gains through the development of layers with higher g-value in the clear state and through the application of appropriate switching strategies.
Keywords: electrochromic glazing; thermochromic glazing; office building; high WWR; energy savings; heating demands; cooling demands; office lighting; EnergyPlus (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2020
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (8)
Downloads: (external link)
https://www.mdpi.com/1996-1073/13/11/3020/pdf (application/pdf)
https://www.mdpi.com/1996-1073/13/11/3020/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:13:y:2020:i:11:p:3020-:d:370379
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().