EconPapers    
Economics at your fingertips  
 

Experimental Investigation of the Prestrike Characteristics of a Double-Break Vacuum Circuit Breaker under DC Voltages

Yun Geng, Xiaofei Yao, Jinlong Dong, Xue Liu, Yingsan Geng, Zhiyuan Liu, Jing Peng and Ke Wang
Additional contact information
Yun Geng: State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, No.28 Xianning West Road, Xi’an 710049, China
Xiaofei Yao: State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, No.28 Xianning West Road, Xi’an 710049, China
Jinlong Dong: State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, No.28 Xianning West Road, Xi’an 710049, China
Xue Liu: State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, No.28 Xianning West Road, Xi’an 710049, China
Yingsan Geng: State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, No.28 Xianning West Road, Xi’an 710049, China
Zhiyuan Liu: State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, No.28 Xianning West Road, Xi’an 710049, China
Jing Peng: Electric Power Research Institute, Yunnan Power Grid Co. Ltd., No.105 Yunda West Road, Kunming 650217, China
Ke Wang: Electric Power Research Institute, Yunnan Power Grid Co. Ltd., No.105 Yunda West Road, Kunming 650217, China

Energies, 2020, vol. 13, issue 12, 1-17

Abstract: The prestrike phenomenon in vacuum circuit breakers (VCBs) is interesting but complicated. Previous studies mainly focus on the prestrike phenomenon in single-break VCBs. However, experimental work on prestrike characteristics of double-break VCBs cannot be found in literature. This paper aims to experimentally determine the probabilistic characteristics of prestrike gaps in a double-break VCB consisting of two commercial vacuum interrupters (VIs) in series under direct current (DC) voltages. As a benchmark, single-break prestrike gaps were measured by short-circuiting one of the VIs in a double break. The experimental results show that the 50% prestrike gap d 50 of each VI in a double break, which is calculated with the complementary Weibull distribution, was significantly reduced by 25% to 72.7% compared with that in a single break. Due to the voltage-sharing effect in the double-break VCB, scatters in prestrike gaps of each VI in a double break was smaller than that in a single break. However, without the sharing-voltage effect, d 50 of the low-voltage side in the double break was 65% higher than that of the same VI in the single break, which could be caused by the asynchronous property of mechanical actuators, the difference of the inherent prestrike characteristics of each VI and the unequal voltage-sharing ratio of VIs.

Keywords: vacuum circuit breaker; double break; prestrike characteristics; vacuum interrupter; prestrike gap (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2020
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/13/12/3217/pdf (application/pdf)
https://www.mdpi.com/1996-1073/13/12/3217/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:13:y:2020:i:12:p:3217-:d:374336

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:13:y:2020:i:12:p:3217-:d:374336