EconPapers    
Economics at your fingertips  
 

Detection Limit of CO Concentration Measurement in LPG/Air Flame Flue Gas Using Tunable Diode Laser Absorption Spectroscopy

Sunghyun So, Jiyeon Park, Aran Song, Jungho Hwang, Miyeon Yoo and Changyeop Lee
Additional contact information
Sunghyun So: Clean Energy System R&D Department, Korea Institute of Industrial Technology, Cheonan 31056, Korea
Jiyeon Park: Clean Energy System R&D Department, Korea Institute of Industrial Technology, Cheonan 31056, Korea
Aran Song: Clean Energy System R&D Department, Korea Institute of Industrial Technology, Cheonan 31056, Korea
Jungho Hwang: Mechanical Engineering Department, Yonsei University, Seoul 03722, Korea
Miyeon Yoo: Clean Energy System R&D Department, Korea Institute of Industrial Technology, Cheonan 31056, Korea
Changyeop Lee: Clean Energy System R&D Department, Korea Institute of Industrial Technology, Cheonan 31056, Korea

Energies, 2020, vol. 13, issue 16, 1-12

Abstract: In a combustion reaction of hydrocarbon fuel, carbon monoxide (CO) is a gas species that is closely related to air pollution generation and combustion efficiency. It has a trade-off with nitrogen oxide and increases rapidly in case of incomplete combustion or in fuel-rich (Φ > 1) environments. Therefore, it is essential to measure CO concentration in order to optimize the combustion condition. In the case of a steel annealing system, the combustion environment is maintained in a deoxidation atmosphere to prevent the formation of an oxide layer on the steel sheet surface. However, it is difficult to measure the CO concentration in a combustion furnace in real-time because of the harsh environment in the furnace. Tunable diode laser absorption spectroscopy, which has the advantages of non-invasiveness, fast response, and in situ measurement-based optical measurement, is highly attractive for measuring the concentration of a certain gas species in a combustion environment. In this study, a combustion system of a partially premixed flamed burner was designed to control the equivalence ratio for fuel-rich conditions. CO concentration was measured using a distributed feedback laser with a wavenumber of 4300.7 cm −1 in the mid-infrared region. The results showed that the CO concentration measured at an equivalence ratio of 1.15 to 1.50 was 0.495% to 6.139%. The detection limit in the combustion environment was analyzed at a path length of 190 cm and an internal temperature of 733 K. The ranges of the peak absorbance were derived as 0.064 and 0.787, which were within the theoretical bounds of 10 −3 and 0.80 when the equivalence ratio was varied from 1.15 to 1.50.

Keywords: carbon monoxide; hydrocarbon; tunable diode laser absorption spectroscopy (TDLAS); detection limit; fuel-rich; peak absorbance (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2020
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/13/16/4234/pdf (application/pdf)
https://www.mdpi.com/1996-1073/13/16/4234/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:13:y:2020:i:16:p:4234-:d:399704

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:13:y:2020:i:16:p:4234-:d:399704