Online Monitoring of Partial Discharges in Power Transformers Using Capacitive Coupling in the Tap of Condenser Bushings
Laerty Damião,
João Guimarães,
Guilherme Ferraz,
Edson Bortoni,
Ronaldo Rossi,
Renato Capelini,
Rogério Salustiano and
Estácio Tavares
Additional contact information
Laerty Damião: High Voltage Equipments—HVEX, Nossa Sra. de Fatima, Itajubá MG 37502-508, Brazil
João Guimarães: Institute of Electrical Systems and Energy, Federal University of Itajubá, Pinheirinho, Itajubá MG 37500-903, Brazil
Guilherme Ferraz: High Voltage Equipments—HVEX, Nossa Sra. de Fatima, Itajubá MG 37502-508, Brazil
Edson Bortoni: Institute of Electrical Systems and Energy, Federal University of Itajubá, Pinheirinho, Itajubá MG 37500-903, Brazil
Ronaldo Rossi: Institute of Electrical Systems and Energy, Federal University of Itajubá, Pinheirinho, Itajubá MG 37500-903, Brazil
Renato Capelini: High Voltage Equipments—HVEX, Nossa Sra. de Fatima, Itajubá MG 37502-508, Brazil
Rogério Salustiano: High Voltage Equipments—HVEX, Nossa Sra. de Fatima, Itajubá MG 37502-508, Brazil
Estácio Tavares: Institute of Electrical Systems and Energy, Federal University of Itajubá, Pinheirinho, Itajubá MG 37500-903, Brazil
Energies, 2020, vol. 13, issue 17, 1-22
Abstract:
Failures in power transformers are one of the most serious occurrences in a power system. Thus, the monitoring of transformers and their ancillary equipment, such as bushings, is of great importance to improving the operational efficiency of these assets. In this context, this paper presents the development of a monitoring system for the measurement of partial discharges (PDs), which are a key parameter in the analysis of insulation condition. PD measurements were performed using the electrical method. For this purpose, a capacitive coupling device was developed for bushings that works as a sensor for high-frequency signals and also as a protection apparatus to guarantee the integrity of the bushings in cases of extreme events, such as lightning surges. In addition, a computational routine is presented that applies a digital filtering process followed by a proposed step for differentiating PDs from noises. For validation, the proposed system was subjected to laboratory tests and field applications, from which the viability of the project and the efficiency in detecting PDs were verified.
Keywords: bushings; monitoring; partial discharges; power transformers; test tap (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2020
References: View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://www.mdpi.com/1996-1073/13/17/4351/pdf (application/pdf)
https://www.mdpi.com/1996-1073/13/17/4351/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:13:y:2020:i:17:p:4351-:d:402761
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().