EconPapers    
Economics at your fingertips  
 

Optimized Protection of Pole-Mounted Distribution Transformers against Direct Lightning Strikes

Mahdi Pourakbari-Kasmaei, Farhan Mahmood and Matti Lehtonen
Additional contact information
Mahdi Pourakbari-Kasmaei: Department of Electrical Engineering and Automation, Aalto University, Maarintie 8, 02150 Espoo, Finland
Farhan Mahmood: Department of Electrical Engineering, University of Engineering and Technology, Lahore 39161, Pakistan
Matti Lehtonen: Department of Electrical Engineering and Automation, Aalto University, Maarintie 8, 02150 Espoo, Finland

Energies, 2020, vol. 13, issue 17, 1-34

Abstract: Direct lightning strikes on overhead phase conductors result in high overvoltage stress on the medium voltage (MV) terminals of pole-mounted transformers, which may cause considerable damage. Therefore, introducing an efficient protection strategy would be a remedy for alleviating such undesirable damages. This paper investigates the optimized protection of MV transformers against direct lightning strikes on the phase conductors. To this end, first, the impacts of grounding densities (number of grounded intermediate poles between every two successive transformer poles) on the probability of overvoltage stress on transformer terminals are investigated. Then, the implications of guy wire, as a supporting device for ungrounded intermediate poles, on reducing the overvoltage stress on transformers, are studied. Finally, the role of a surge arrester in mitigating the overvoltage stress of non-surge-arrester-protected transformer poles is scrutinized. The investigations are conducted on a sample MV network with 82 wood poles comprising 17 pole-mounted transformers protected by spark gaps. To provide in-depth analysis, two different poles, namely creosote- and arsenic-impregnated poles, are considered under wet and dry weather conditions. A sensitivity analysis is performed on grounding distances and on a combination of guy wire and grounded intermediate poles while taking into account soil ionization. The results provide a clear picture for the system operator in deciding how many grounded intermediate poles might be required for a system to reach the desired probabilities of transformers experiencing overvoltage stress and how the surge arrester and guy wires contribute to mitigating undesirable overvoltage stress.

Keywords: direct lightning; guy wire; grounding density; pole-mounted transformer; spark gap; surge arrester (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2020
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/1996-1073/13/17/4372/pdf (application/pdf)
https://www.mdpi.com/1996-1073/13/17/4372/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:13:y:2020:i:17:p:4372-:d:403441

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:13:y:2020:i:17:p:4372-:d:403441