EconPapers    
Economics at your fingertips  
 

Defrosting Performance Improvement of Air-Source Heat Pump Combined Refrigerant Direct-Condensation Radiant Floor Heating System with Phase Change Material

Chenxiao Zheng, Shijun You, Huan Zhang, Zeqin Liu, Wandong Zheng, Zhenjing Wu and Man Fan
Additional contact information
Chenxiao Zheng: School of Environmental Science and Engineering, Tianjin University, Tianjin 300350, China
Shijun You: School of Environmental Science and Engineering, Tianjin University, Tianjin 300350, China
Huan Zhang: School of Environmental Science and Engineering, Tianjin University, Tianjin 300350, China
Zeqin Liu: School of Mechanical Engineering, Tianjin University of Commerce, Tianjin 300134, China
Wandong Zheng: School of Environmental Science and Engineering, Tianjin University, Tianjin 300350, China
Zhenjing Wu: School of Environmental Science and Engineering, Tianjin University, Tianjin 300350, China
Man Fan: School of Energy and Environmental Engineering, Hebei University of Technology, Tianjin 300401, China

Energies, 2020, vol. 13, issue 18, 1-17

Abstract: Traditional defrosting methods applied to solve frosting problems of air-source heat pumps operating in cold periods may reduce heat capacity of the system and decrease indoor thermal comfort. In order to improve the performance of air-source heat pump (ASHP) and maintain indoor temperature in defrosting conditions, an air-source heat pump combined with a refrigerant direct-condensation radiant floor heating system with phase change material is proposed and evaluated in this study. Two radiant floor heating terminals with and without composite phase change material modules were compared through experiments. A composite phase change material based on dodecanoic acid-tetradecanol-hexadecanol mixture and expanded graphite was investigated for this application. Experimental results indicate that both heat fluxes of two comparing terminals are higher than 70 W/m 2 in heating condition. At the same time, the floor surface temperature, indoor air temperature, and heating capacity of the terminal with composite phase change material modules are higher than those without composite phase change material modules in defrosting condition. This suggests that the proposed system with composite phase change material modules can improve indoor thermal comfort in defrosting condition as well as satisfy the heating requirement in heating condition.

Keywords: ASHP system; refrigerant direct-condensation radiant floor heating; CPCM; defrosting; indoor thermal comfort (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2020
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (2)

Downloads: (external link)
https://www.mdpi.com/1996-1073/13/18/4594/pdf (application/pdf)
https://www.mdpi.com/1996-1073/13/18/4594/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:13:y:2020:i:18:p:4594-:d:408715

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:13:y:2020:i:18:p:4594-:d:408715