Energies, 2020, vol. 13, issue 18, 1-18

Abstract: The stability of the control grid is a critical prerequisite for a safe and efficient power system service. A thorough knowledge of the effects of the power system volatility is essential for the effective study and control of power systems. This paper presents the simulation outcome of a multimachine power network implemented by a wind farm (WF) utilizing a static synchronous compensator (STATCOM) for better stability control objectives. A similarly aggregated double-fed induction generator (DFIG) powered by a gearbox analogy with an equally aggregated wind turbine (WT) determines the operating output of the wind farm. A proportional–integral–derivative controller (PID)-based damping controller, PID including Fuzzy Logic Controller (FLC), and an adaptive network-based fuzzy inference system (ANFIS) controller of the proposed SATCOM are intended to add sufficient damping properties to the dominating modes of the examined system during diverse working circumstances. To assess the feasibility of the suggested control schemes, a frequency-domain method concentrated on a linearized mathematical structure layout utilizing a time-domain strategy centered on a nonlinear configuration of the device that is subjected to severe fault on the attached bus was carried out consistently. A STATCOM damping controller is configured using the ANFIS method to apply appropriate damping properties to the device’s decisive modes being evaluated under various test conditions. From the findings of the comparative simulation, it can be inferred that the suggested STATCOM along with the planned ANFIS is seen as comparable to STATCOM with PID and STATCOM with PID plus FLC to increase the stability of the studied device.

Keywords: DFIG-based wind farm; three-machine nine-bus system; STATCOM; stability; fuzzy logic controller; adaptive network-based fuzzy inference system (ANFIS) (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2020
References: View complete reference list from CitEc
Citations: View citations in EconPapers (3)

Downloads: (external link)
https://www.mdpi.com/1996-1073/13/18/4707/pdf (application/pdf)
https://www.mdpi.com/1996-1073/13/18/4707/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:13:y:2020:i:18:p:4707-:d:411325

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:13:y:2020:i:18:p:4707-:d:411325