Application of Dissolved Gas Analysis in Assessing Degree of Healthiness or Faultiness with Fault Identification in Oil-Immersed Equipment
George Kimani Irungu and
Aloys Oriedi Akumu
Additional contact information
George Kimani Irungu: Department of Electrical Engineering, Tshwane University of Technology, Pretoria West Private Bag X680, Pretoria 0001, South Africa
Aloys Oriedi Akumu: Department of Electrical Engineering, Tshwane University of Technology, Pretoria West Private Bag X680, Pretoria 0001, South Africa
Energies, 2020, vol. 13, issue 18, 1-24
Abstract:
The healthiness and or faultiness of oil-immersed electrical equipment using dissolved gas characterization has remained a critical and challenging task in power systems. Dissolved gas analysis (DGA) continues to be the utmost preferred technique of detecting mainly slow evolving thermal and electrical faults. However, DGA can reveal more than just faults in equipment. This research looks at broad areas where DGA can be applied to determine the healthiness or faultiness of equipment in addition to fault identification. In equipment considered normal—i.e., fault-free—DGA can give the degree of healthiness (DOH) based on Rogers ratios C 2 H 2 /C 2 H 4 < 0.1, 0.1 < CH 4 /H 2 < 1, and C 2 H 4 /C 2 H 6 < 1, plus the 3 < CO 2 /CO < 10 ratio for identifying fault-free devices. This answers the question: How healthy or normal is the equipment? Similarly, when these ratios are violated, it signifies the presence of faults, and two things ought to be determined. One is to identify the type of fault(s), which has been the norm. The other thing that can be evaluated is the degree of faultiness (DOF), based on the extent to which the ratios have been violated. Rarely has this been done. This might answer the question for the same fault class: How severe is the fault? To synthesize the DOH and/or DOF, fuzzy logic is applied. To diagnose faults, fuzzy logic and fuzzy-evidential tools are proposed. The accuracy and effectiveness of the proposed fuzzy techniques are better than those of the IEC60599 and Rogers methods, and they are comparable to those of the Duval Triangle 1 and Pentagon 1 methods using the six IEC faults. Results from DOF evaluation have shown electrical faults to be more impactful relative to the rest.
Keywords: degree of faultiness (DOF); degree of healthiness (DOH); dissolved gas analysis (DGA); evidential reasoning criterion; fault diagnosis; fuzzy logic (FL); fuzzy characterization curves; probability value assignments (PVAs) (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2020
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://www.mdpi.com/1996-1073/13/18/4770/pdf (application/pdf)
https://www.mdpi.com/1996-1073/13/18/4770/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:13:y:2020:i:18:p:4770-:d:412822
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().