Experimental Investigation of the Air Exchange Effectiveness of Push-Pull Ventilation Devices
Sven Auerswald,
Carina Hörberg,
Thibault Pflug,
Jens Pfafferott,
Constanze Bongs and
Hans-Martin Henning
Additional contact information
Sven Auerswald: Fraunhofer Institute for Solar Energy Systems ISE, 79110 Freiburg, Germany
Carina Hörberg: Fraunhofer Institute for Solar Energy Systems ISE, 79110 Freiburg, Germany
Thibault Pflug: Fraunhofer Institute for Solar Energy Systems ISE, 79110 Freiburg, Germany
Jens Pfafferott: Institute of Energy Systems Technology (INES), Faculty of Mechanical and Process Engineering, Offenburg University of Applied Sciences, 77652 Offenburg, Germany
Constanze Bongs: Fraunhofer Institute for Solar Energy Systems ISE, 79110 Freiburg, Germany
Hans-Martin Henning: Fraunhofer Institute for Solar Energy Systems ISE, 79110 Freiburg, Germany
Energies, 2020, vol. 13, issue 21, 1-21
Abstract:
The increasing installation numbers of ventilation units in residential buildings are driven by legal objectives to improve their energy efficiency. The dimensioning of a ventilation system for nearly zero energy buildings is usually based on the air flow rate desired by the clients or requested by technical regulations. However, this does not necessarily lead to a system actually able to renew the air volume of the living space effectively. In recent years decentralised systems with an alternating operation mode and fairly good energy efficiencies entered the market and following question was raised: “Does this operation mode allow an efficient air renewal?” This question can be answered experimentally by performing a tracer gas analysis. In the presented study, a total of 15 preliminary tests are carried out in a climatic chamber representing a single room equipped with two push-pull devices. The tests include summer, winter and isothermal supply air conditions since this parameter variation is missing till now for push-pull devices. Further investigations are dedicated to the effect of thermal convection due to human heat dissipation on the room air flow. In dependence on these boundary conditions, the determined air exchange efficiency varies, lagging behind the expected range 0.5 < ε a < 1 in almost all cases, indicating insufficient air exchange including short-circuiting. Local air exchange values suggest inhomogeneous air renewal depending on the distance to the indoor apertures as well as the temperature gradients between in- and outdoor. The tested measurement set-up is applicable for field measurements.
Keywords: decentralised ventilation; ventilation effectiveness; air exchange efficiency; push-pull (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2020
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/13/21/5817/pdf (application/pdf)
https://www.mdpi.com/1996-1073/13/21/5817/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:13:y:2020:i:21:p:5817-:d:441146
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().