EconPapers    
Economics at your fingertips  
 

Performance Enhancement of a Sludge Continuous Feed Heat Pump Drying System by Air Deflectors and Auxiliary Cooling Subsystems

Win-Jet Luo, Cheng-Yan Lin, Nai-Feng Wu and Zhi-Qun Xu
Additional contact information
Win-Jet Luo: Graduate Institute of Precision Manufacturing, National Chin-Yi University of Technology, Taichung 41170, Taiwan
Cheng-Yan Lin: Department of Refrigeration, Air Conditioning and Energy Engineering, National Chin-Yi University of Technology, Taichung 41170, Taiwan
Nai-Feng Wu: Department of Refrigeration, Air Conditioning and Energy Engineering, National Chin-Yi University of Technology, Taichung 41170, Taiwan
Zhi-Qun Xu: Department of Refrigeration, Air Conditioning and Energy Engineering, National Chin-Yi University of Technology, Taichung 41170, Taiwan

Energies, 2020, vol. 13, issue 24, 1-22

Abstract: This study proposes an improved design for a typical sludge continuous feeding drying system connected with three air-source heat pumps. The system’s performance was further improved using air-deflectors on the drying chamber’s internal sidewalls, enhancing the heat and mass transfer between the conveyor sludge and circulating airflow. In this study, numerical analysis was performed to elucidate the deflector designs on the airflow field and thermal temperature field distributions in the drying chamber. The specific moisture extraction rate ( SMER ) value was quantified to evaluate the system’s overall improvement during experiments. With a suitable deflector design, the average percent water content in sludge could be further reduced to 22.2% with drying time of 18.3 h, and the SMER value could be enhanced from 1.38 kg/kWh to as high as 1.83 kg/kWh with an increment of 32.44%. Moreover, to prevent overloading and frequent shutdown of the compressors, an auxiliary cooling subsystem was designed to attain stable operational conditions. By the auxiliary cooling subsystem design, the compressors’ shutdown can be avoided, the temperature difference between airflow inlets and outlet of the drying chamber can be increased, and SMER value can be further increased to a value of 1.94 kg/kWh.

Keywords: sludge; heat pump; auxiliary cooling; specific moisture extraction rate (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2020
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (2)

Downloads: (external link)
https://www.mdpi.com/1996-1073/13/24/6651/pdf (application/pdf)
https://www.mdpi.com/1996-1073/13/24/6651/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:13:y:2020:i:24:p:6651-:d:463366

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:13:y:2020:i:24:p:6651-:d:463366