EconPapers    
Economics at your fingertips  
 

Assessment of Reducing Pollutant Emissions in Selected Heating and Ventilation Systems in Single-Family Houses

Joanna Hałacz, Aldona Skotnicka-Siepsiak and Maciej Neugebauer
Additional contact information
Joanna Hałacz: Department of Electrical Engineering, Power Engineering, Electronics and Automation, Faculty of Technical Sciences, University of Warmia and Mazury in Olsztyn, Oczapowskiego str. 2, 10-719 Olsztyn, Poland
Aldona Skotnicka-Siepsiak: Department of Building Engineering, Faculty of Geodesy, Geospatial and Civil Engineering, University of Warmia and Mazury in Olsztyn, Oczapowskiego str. 2, 10-719 Olsztyn, Poland
Maciej Neugebauer: Department of Electrical Engineering, Power Engineering, Electronics and Automation, Faculty of Technical Sciences, University of Warmia and Mazury in Olsztyn, Oczapowskiego str. 2, 10-719 Olsztyn, Poland

Energies, 2020, vol. 13, issue 5, 1-19

Abstract: The article presents the results of a study aiming to select the optimal source of heat for a newly designed single-family home. Commercial software was used to compare heating and ventilation systems involving a bituminous coal boiler, a condensing gas boiler, a biomass boiler, a heat pump with water and glycol as heat transfer media. The effectiveness of natural ventilation, mechanical ventilation with a ground-coupled heat exchanger, and solar heater panels for water heating were evaluated. The analysis was based on the annual demand for useful energy, final energy, and non-renewable primary energy in view of the pollution output of the evaluated heating systems. The analysis revealed that the heat pump with water and glycol was the optimal solution. However, the performance of the heat pump in real-life conditions was below its maximum theoretical efficiency. The biomass boiler contributed to the highest reduction in pollutant emissions (according to Intergovernmental Panel on Climate Change Change guidelines, carbon dioxide emissions have zero value), but it was characterized by the highest demand for final energy. Mechanical ventilation with heat recovery was required in all analyzed systems to achieve optimal results. The introduction of mechanical ventilation decreased the demand for final energy by 10% to around 40% relative to the corresponding heating systems with natural ventilation.

Keywords: exploitation of energy sources; heating and ventilation systems; pollutant emissions; reduction of pollutant emissions; single-family houses (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2020
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (8)

Downloads: (external link)
https://www.mdpi.com/1996-1073/13/5/1224/pdf (application/pdf)
https://www.mdpi.com/1996-1073/13/5/1224/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:13:y:2020:i:5:p:1224-:d:329479

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:13:y:2020:i:5:p:1224-:d:329479