EconPapers    
Economics at your fingertips  
 

Optimum Organic Rankine Cycle Design for the Application in a CHP Unit Feeding a District Heating Network

Lisa Branchini, Andrea De Pascale, Francesco Melino and Noemi Torricelli
Additional contact information
Lisa Branchini: Department of Industrial Engineering, Alma Mater Studiorum—Università di Bologna, viale del Risorgimento 2, 40136 Bologna, Italy
Andrea De Pascale: Department of Industrial Engineering, Alma Mater Studiorum—Università di Bologna, viale del Risorgimento 2, 40136 Bologna, Italy
Francesco Melino: Department of Industrial Engineering, Alma Mater Studiorum—Università di Bologna, viale del Risorgimento 2, 40136 Bologna, Italy
Noemi Torricelli: Department of Industrial Engineering, Alma Mater Studiorum—Università di Bologna, viale del Risorgimento 2, 40136 Bologna, Italy

Energies, 2020, vol. 13, issue 6, 1-22

Abstract: Improvement of energy conversion efficiency in prime movers has become of fundamental importance in order to respect EU 2020 targets. In this context, hybrid power plants comprising combined heat and power (CHP) prime movers integrated with the organic Rankine cycle (ORC) create interesting opportunities to additionally increase the first law efficiency and flexibility of the system. The possibility of adding supplementary electric energy production to a CHP system, by converting the prime movers’ exhaust heat with an ORC, was investigated. The inclusion of the ORC allowed operating the prime movers at full-load (thus at their maximum efficiency), regardless of the heat demand, without dissipating not required high enthalpy-heat. Indeed, discharged heat was recovered by the ORC to produce additional electric power at high efficiency. The CHP plant in its original arrangement (comprising three internal combustion engines of 8.5 MW size each) was compared to a new one, involving an ORC, assuming three different layout configurations and thus different ORC off-design working conditions at user thermal part-load operation. Results showed that the performance of the ORC, on the year basis, strongly depended on its part-load behavior and on its regulation limits. Indeed, the layout that allowed to produce the maximum amount of ORC electric energy per year (about 10 GWh/year) was the one that could operate for the greatest number of hours during the year, which was different from the one that exhibited the highest ORC design power. However, energetic analysis demonstrated that all the proposed solutions granted to reduce the global primary energy consumption of about 18%, and they all proved to be a good investment since they allowed to return on the investment in barely 5 years, by selling the electric energy at a minimum price equal to 70 EUR/MWh.

Keywords: organic Rankine cycle; waste heat recovery; internal combustion engine; cogeneration; district heating (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2020
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/1996-1073/13/6/1314/pdf (application/pdf)
https://www.mdpi.com/1996-1073/13/6/1314/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:13:y:2020:i:6:p:1314-:d:331598

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:13:y:2020:i:6:p:1314-:d:331598