A New Simulation Model for Vertical Spiral Ground Heat Exchangers Combining Cylindrical Source Model and Capacity Resistance Model

Takao Katsura, Takashi Higashitani, Yuzhi Fang, Yoshitaka Sakata, Katsunori Nagano, Hitoshi Akai and Motoaki Oe
Additional contact information
Takao Katsura: Faculty of Engineering, Hokkaido University, N13-W8, Kita-ku, Sapporo 060-8628, Japan
Takashi Higashitani: Faculty of Engineering, Hokkaido University, N13-W8, Kita-ku, Sapporo 060-8628, Japan
Yuzhi Fang: Faculty of Engineering, Hokkaido University, N13-W8, Kita-ku, Sapporo 060-8628, Japan
Yoshitaka Sakata: Faculty of Engineering, Hokkaido University, N13-W8, Kita-ku, Sapporo 060-8628, Japan
Katsunori Nagano: Faculty of Engineering, Hokkaido University, N13-W8, Kita-ku, Sapporo 060-8628, Japan
Hitoshi Akai: Faculty of Engineering, Hokkaido University, N13-W8, Kita-ku, Sapporo 060-8628, Japan
Motoaki Oe: INOAC Housing & Construction Materials Co., Ltd., 4-9-27 Taihou, Atsuta-ku, Nagoya 456-0062, Japan

Energies, 2020, vol. 13, issue 6, 1-17

Abstract: Considering the heat capacity inside vertical spiral ground heat exchanger (VSGHEX) in the simulation is one of the most noteworthy challenge to design the ground source heat pump (GSHP) system with VSGHEXs. In this paper, a new simulation model for VSGHEXs is developed by combining the ICS model with the CaRM. The developed simulation model can consider the heat capacity inside VSGHEX and provide dynamic calculation with high speed and appropriate precision. In order to apply the CaRM, the equivalent length was introduced. Then, the equivalent length was approximated by comparing the results of the CaRM and the numerical calculation. In addition, the calculation model of the VSGHEX was integrated into the design and simulation tool for the GSHP system. The accuracy of the tool was verified by comparing with the measurements. The error between supply temperatures of the measurements and calculation is approximately 2 °C at the maximum. Finally, assuming GSHP systems with VSGHEXs, whose spiral diameter was 500 mm and depth was 4 m, were installed in residential houses in Japan, the required numbers of VSGHEXs were estimated. The results showed a strong correlation between the total heating or cooling load and the required number. Therefore, the required number can be estimated by using the simplified approximate equation.

Keywords: ground source heat pump system; vertical spiral ground heat exchanger; borehole thermal storage; infinite cylindrical source; capacity resistance model (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2020
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (3)

Downloads: (external link)
https://www.mdpi.com/1996-1073/13/6/1339/pdf (application/pdf)
https://www.mdpi.com/1996-1073/13/6/1339/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:13:y:2020:i:6:p:1339-:d:332204

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:13:y:2020:i:6:p:1339-:d:332204