Effect of Existing Façade’s Construction and Orientation on the Performance of Low-E-Based Retrofit Double Glazing in Tropical Climate
Sivanand Somasundaram,
Sundar Raj Thangavelu and
Alex Chong
Additional contact information
Sivanand Somasundaram: Experimental Power Grid Centre, Energy Research Institute, Nanyang Technological University, Singapore 627590, Singapore
Sundar Raj Thangavelu: Experimental Power Grid Centre, Energy Research Institute, Nanyang Technological University, Singapore 627590, Singapore
Alex Chong: Experimental Power Grid Centre, Energy Research Institute, Nanyang Technological University, Singapore 627590, Singapore
Energies, 2020, vol. 13, issue 8, 1-14
Abstract:
This paper investigates the effect of an existing façade’s construction (viz. clear/grey/solar film, with and without external shade) and orientation on the performance of low-e (hard coat)-based retrofit double glazing in a tropical climate. The performance of double-glazed façades is characterized by the ability to reduce solar heat gain and the consequent reduction in power consumption of air-conditioning systems. This study involves a real-life test-bedding of a low-e (hard coat)-based retrofit double-glazing façade for a few specific cases—clear glass southeast façade without shade, clear glass southwest façade with external shade, and northwest façade with solar film and external shade. Subsequently, energy modelling simulations were done to analyze other scenarios involving various combinations of façade orientation (north, south, west, and east) and façade material (clear glass, tinted grey glass, clear glass with solar film) with and without external sunshades. The east/west-facing façades had a higher impact on the retrofit solution, and more so when the existing façade was of tinted glass or with solar film. For the case analyzed, with a window-to-wall ratio of 8% (based on overall building envelope), a grey tinted east-facing façade could benefit from annual average HVAC energy savings of up to 5.9%.
Keywords: retrofit double glazing; energy savings; façade direction; test bedding; energy model (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2020
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://www.mdpi.com/1996-1073/13/8/2016/pdf (application/pdf)
https://www.mdpi.com/1996-1073/13/8/2016/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:13:y:2020:i:8:p:2016-:d:347207
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().