Investigation and Improvement of Standard External Lightning Protection System: Industrial Case Study
I Made Yulistya Negara,
Daniar Fahmi,
Dimas Anton Asfani,
Satriyadi Hernanda Ign,
Rendi Bagus Pratama and
Arief Budi Ksatria
Additional contact information
I Made Yulistya Negara: Department of Electrical Engineering, Faculty of Intelligent Electrical and Informatic Technology, Institut Teknologi Sepuluh Nopember, Surabaya 60111, Indonesia
Daniar Fahmi: Department of Electrical Engineering, Faculty of Intelligent Electrical and Informatic Technology, Institut Teknologi Sepuluh Nopember, Surabaya 60111, Indonesia
Dimas Anton Asfani: Department of Electrical Engineering, Faculty of Intelligent Electrical and Informatic Technology, Institut Teknologi Sepuluh Nopember, Surabaya 60111, Indonesia
Satriyadi Hernanda Ign: Department of Electrical Engineering, Faculty of Intelligent Electrical and Informatic Technology, Institut Teknologi Sepuluh Nopember, Surabaya 60111, Indonesia
Rendi Bagus Pratama: Department of Electrical Engineering, Faculty of Intelligent Electrical and Informatic Technology, Institut Teknologi Sepuluh Nopember, Surabaya 60111, Indonesia
Arief Budi Ksatria: Department of Electrical Engineering, Faculty of Intelligent Electrical and Informatic Technology, Institut Teknologi Sepuluh Nopember, Surabaya 60111, Indonesia
Energies, 2021, vol. 14, issue 14, 1-12
Abstract:
In this study, the lightning protection system and grounding system of one plant of the petrochemical industry were investigated, evaluated, and improved. The methods used in this study were rolling sphere and angle protection methods. The grounding system of the building under study was modeled and simulated using ATP/EMTP (Alternative Transient Program/Electromagnetic Transient Program) software. The results show that the external lightning protection system of the prilling tower studied does not adhere to IEC 62305 and IEC 1024-1-1 standards. Moreover, the grounding configuration of the DCS building was not appropriate for protecting sensitive equipment inside. Lightning causes an enormous potential difference between lightning ground rods in the grounding system. Additionally, disabling the existing surge protective device (SPD) causes an increase in the magnitude of Ground Potential Rise at the DCS building. Improvement of the lightning protection system of the prilling tower and DCS building on Plant 1 of this petrochemical company as well as some other recommendations for improvements are proposed. This paper also shows evidence that external lightning protection, internal lightning protection, and the grounding system need to be connected to make an exemplary lightning protection system.
Keywords: lightning; lightning protection system; grounding system; surge protective device; rolling sphere method; ATP/EMTP (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/14/14/4118/pdf (application/pdf)
https://www.mdpi.com/1996-1073/14/14/4118/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:14:y:2021:i:14:p:4118-:d:590604
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().