EconPapers    
Economics at your fingertips  
 

Environmentally Constrained Optimal Dispatch Method for Combined Cooling, Heating, and Power Systems Using Two-Stage Optimization

Haesung Jo, Jaemin Park and Insu Kim
Additional contact information
Haesung Jo: School of Electrical Engineering, Inha University, Incheon 22212, Korea
Jaemin Park: School of Electrical Engineering, Inha University, Incheon 22212, Korea
Insu Kim: School of Electrical Engineering, Inha University, Incheon 22212, Korea

Energies, 2021, vol. 14, issue 14, 1-20

Abstract: The reliance on coal-fired power generation has gradually reduced with the growing interest in the environment and safety, and the environmental effects of power generation are now being considered. However, it can be difficult to provide stable power to end-users while minimizing environmental pollution by replacing coal-fired systems with combined cooling, heat, and power (CCHP) systems that use natural gas, because CCHP systems have various power output vulnerabilities. Therefore, purchasing power from external electric grids is essential in areas where CCHP systems are built; hence, optimal CCHP controls should also consider energy purchased from external grids. This study proposes a two-stage algorithm to optimally control CCHP systems. In Stage One, the optimal energy mix using the Lagrange multiplier method for state-wide grids from which CCHP systems purchase deficient electricity was calculated. In Stage Two, the purchased volumes from these grids were used as inputs to the proposed optimization algorithm to optimize CCHP systems suitable for metropolitan areas. We used case studies to identify the accurate energy efficiency, costs, and minimal emissions. We chose the Atlanta area to analyze the CCHP system’s impact on energy efficiency, cost variation, and emission savings. Then, we calculated an energy mix suitable for the region for each simulation period. The case study results confirm that deploying an optimized CCHP system can reduce purchased volumes from the grid while reducing total emissions. We also analyzed the impact of the CCHP system on emissions and cost savings.

Keywords: absorption chiller; combined cooling; heating; and power; emission; microturbine (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (3)

Downloads: (external link)
https://www.mdpi.com/1996-1073/14/14/4135/pdf (application/pdf)
https://www.mdpi.com/1996-1073/14/14/4135/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:14:y:2021:i:14:p:4135-:d:591076

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:14:y:2021:i:14:p:4135-:d:591076