EconPapers    
Economics at your fingertips  
 

An Adaptive Early Fault Detection Model of Induced Draft Fans Based on Multivariate State Estimation Technique

Ruijun Guo, Guobin Zhang, Qian Zhang, Lei Zhou, Haicun Yu, Meng Lei and You Lv
Additional contact information
Ruijun Guo: Inner Mongolia Power Research Institute, Hohhot 010020, China
Guobin Zhang: Inner Mongolia Power Research Institute, Hohhot 010020, China
Qian Zhang: Inner Mongolia Power Research Institute, Hohhot 010020, China
Lei Zhou: Inner Mongolia Power Research Institute, Hohhot 010020, China
Haicun Yu: Inner Mongolia Power Research Institute, Hohhot 010020, China
Meng Lei: School of Control and Computer Engineering, North China Electric Power University, Beijing 102206, China
You Lv: School of Control and Computer Engineering, North China Electric Power University, Beijing 102206, China

Energies, 2021, vol. 14, issue 16, 1-18

Abstract: The induced draft (ID) fan is an important piece of auxiliary equipment in coal-fired power plants. Early fault detection of the ID fan can provide predictive maintenance and reduce unscheduled shutdowns, thus improving the reliability of the power generation. In this study, an adaptive model was developed to achieve the early fault detection of ID fans. First, a non-parametric monitoring model was constructed to describe the normal operating characteristics with the multivariate state estimation technique (MSET). A similarity index representing operation status was defined according to the prediction deviations to produce warnings of early faults. To deal with the model accuracy degradation because of variant condition operation of the ID fan, an adaptive strategy was proposed by using the samples with a high data quality index (DQI) to manage the memory matrix and update the MSET model, thereby improving the fault detection results. The proposed method was applied to a 300 MW coal-fired power plant to achieve the early fault detection of an ID fan. In addition, fault detection by using the model without an update was also compared. Results show that the update strategy can greatly improve the MSET model accuracy when predicting normal operations of the ID fan; accordingly, the fault can be detected more than 4 h earlier by using the strategy with the adaptive update when compared to the model without an update.

Keywords: fault detection; induced draft fan; multivariate state estimation technique; model update; coal-fired power plant (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/14/16/4787/pdf (application/pdf)
https://www.mdpi.com/1996-1073/14/16/4787/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:14:y:2021:i:16:p:4787-:d:609768

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:14:y:2021:i:16:p:4787-:d:609768