A Modified Grid-Connected Inverter Topology for Power Oscillation Suppression under Unbalanced Grid Voltage Faults
Cheng Luo,
Xikui Ma,
Lihui Yang,
Yongming Li,
Xiaoping Yang,
Junhui Ren and
Yanmei Zhang
Additional contact information
Cheng Luo: State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049, China
Xikui Ma: State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049, China
Lihui Yang: State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049, China
Yongming Li: State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049, China
Xiaoping Yang: Xi’an XD Power System Co., Ltd., Xi’an 710075, China
Junhui Ren: Xi’an XD Power System Co., Ltd., Xi’an 710075, China
Yanmei Zhang: Xi’an XD Power System Co., Ltd., Xi’an 710075, China
Energies, 2021, vol. 14, issue 16, 1-17
Abstract:
Under unbalanced grid voltage faults, the output power oscillation of a grid-connected inverter is an urgent problem to be solved. In the traditional topology of inverters, it is impossible to eliminate power oscillation and simultaneously maintain balanced output current waveform. In this paper, considering the solvability of reference current matrix equation, the inherent mechanism of inverter output power oscillation is analyzed, and a modified topology with auxiliary modules inserted in series between the inverter output filter and the point of common coupling (PCC) is proposed. Due to the extra controllable freedoms provided by auxiliary modules, the inverter could generate extra voltage to correct PCC voltage while keeping balance of output current, so as to eliminate the oscillation of output power. Simulation and experimental results verify the effectiveness of the proposed topology.
Keywords: modified gird-connected inverter topology; negative-sequence component; power oscillation; unbalanced grid voltage fault (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2021
References: View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://www.mdpi.com/1996-1073/14/16/5057/pdf (application/pdf)
https://www.mdpi.com/1996-1073/14/16/5057/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:14:y:2021:i:16:p:5057-:d:616293
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().