Experimental and Computational Model for a Neonatal Incubator with Thermoelectric Conditioning System
Alejandro Rincón Casado,
Mauricio Larrodé-Díaz,
Francisco Fernandez Zacarias and
Ricardo Hernández Molina
Additional contact information
Alejandro Rincón Casado: Department of Mechanics and Industrial Design, College of Engineering, University of Cadiz, 11510 Puerto Real, Spain
Mauricio Larrodé-Díaz: Department of Mechanics and Industrial Design, College of Engineering, University of Cadiz, 11510 Puerto Real, Spain
Francisco Fernandez Zacarias: Department of Mechanics and Industrial Design, College of Engineering, University of Cadiz, 11510 Puerto Real, Spain
Ricardo Hernández Molina: Thermal Engines and Machines Department, College of Engineering, University of Cadiz, 11510 Puerto Real, Spain
Energies, 2021, vol. 14, issue 17, 1-16
Abstract:
This work describes the design, construction and testing of a thermo-electric conditioning device installed in a neonatal incubator with the aim of improving the precision in the regulation of the interior air temperature, reducing noise and interior vibration, and improving the life of the neonate. A simplified one-dimensional thermal model has been developed, made up of resistances and thermal capacities that simulate the thermal behaviour of all the elements of the system from end to end. All the equations of the model are obtained in a nodal way, allowing the mathematical relationship between the input and output to be known. This model makes it possible to improve temperature control, avoiding the deviations that occur in the traditional model controlled by sensors at both ends. The computational model allows to predict the variation of temperatures in transient and permanent regime. This model allows the design and sizing of the thermoelectric system for different outdoor environmental conditions and the selection of the number of Peltier modules needed to satisfy the heating demand of other incubators with different geometry and capacity. The results of the computational model show good agreement with the experimental tests, despite being a simplified 1D nodal model. The results obtained show a coefficient of operation (COP) of 1.38, achieving higher performance than the current traditional electrical resistance system (COP = 1). In addition, a CFD study has been carried out to check the air patterns, to see the temperature uniformity and to estimate the number of air changes per hour (HVAC) inside the incubator.
Keywords: thermal comfort; neonatal incubators; Peltier effect; dynamic simulation; experimental testing; thermoelectric system (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/14/17/5278/pdf (application/pdf)
https://www.mdpi.com/1996-1073/14/17/5278/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:14:y:2021:i:17:p:5278-:d:621996
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().