Influence of Arc Size on the Ignition and Flame Propagation of Cable Fire
Chenying Li,
Jie Chen,
Wei Zhang,
Libing Hu,
Jingying Cao,
Jianjun Liu,
Zhenyu Zhu and
Shuqun Wu
Additional contact information
Chenying Li: Electric Power Research Institute of State Grid Jiangsu Electric Power Co., Ltd., Nanjing 211103, China
Jie Chen: Electric Power Research Institute of State Grid Jiangsu Electric Power Co., Ltd., Nanjing 211103, China
Wei Zhang: Electric Power Research Institute of State Grid Jiangsu Electric Power Co., Ltd., Nanjing 211103, China
Libing Hu: Electric Power Research Institute of State Grid Jiangsu Electric Power Co., Ltd., Nanjing 211103, China
Jingying Cao: Electric Power Research Institute of State Grid Jiangsu Electric Power Co., Ltd., Nanjing 211103, China
Jianjun Liu: Electric Power Research Institute of State Grid Jiangsu Electric Power Co., Ltd., Nanjing 211103, China
Zhenyu Zhu: College of Automation Engineering, Nanjing University of Aeronautics & Astronautics, Nanjing 211106, China
Shuqun Wu: College of Automation Engineering, Nanjing University of Aeronautics & Astronautics, Nanjing 211106, China
Energies, 2021, vol. 14, issue 18, 1-14
Abstract:
Cable fire caused by arc faults is one of the essential factors threatening the safe operation of a power system. The ignition and flame propagation of cable fire dependent on the characteristics of the arc discharge is lackingin in-depth understanding at present. In this work, with the constant electric power deposited into the arc discharge, the effects of arc size on the ignition and flame propagation of 110 kV XLPE cable fire are investigated for the first time. The arc size is changed by varying the gap distance of electrodes from 1.5 cm to 2.5 cm. It is interesting to find that the larger the arc size is, the faster the cable fire is ignited and propagates, and the larger the damaged area of the sheath of the cable is. Therein, when the gap distance increases from 1.3 cm to 3.1 cm, the equivalent impedance and the length of the arc discharge increase nearly seven times and three times, respectively. However, the gas temperature of the arc decreases slightly from 2280 K to 2100 K. In addition, a 3D model of the cable fire ignited by arc discharge is computed by Pyrosim software with fire dynamic simulation (FDS) module. Simulated results show that as the arc size increases, the cable fire is ignited faster, the flame propagates both vertically and horizontally increasing significantly, which is agreed well with the experimental results. This study deepens the understanding of the cable fire ignited by arc discharge and therefore it is useful for the evaluation and prevention of cable fire.
Keywords: arc discharge; high-voltage cable; fire simulation; fire ignition; flame propagation (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://www.mdpi.com/1996-1073/14/18/5675/pdf (application/pdf)
https://www.mdpi.com/1996-1073/14/18/5675/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:14:y:2021:i:18:p:5675-:d:632220
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().