Evaluation Method for Winding Performance of Distribution Transformer
Chunguang Suo,
Yanan Ren,
Wenbin Zhang,
Yincheng Li,
Yanyun Wang and
Yi Ke
Additional contact information
Chunguang Suo: College of Science, Kunming University of Science and Technology, Kunming 650504, China
Yanan Ren: College of Science, Kunming University of Science and Technology, Kunming 650504, China
Wenbin Zhang: College of Mechanical and Electrical Engineering, Kunming University of Science and Technology, Kunming 650504, China
Yincheng Li: College of Science, Kunming University of Science and Technology, Kunming 650504, China
Yanyun Wang: College of Science, Kunming University of Science and Technology, Kunming 650504, China
Yi Ke: College of Mechanical and Electrical Engineering, Kunming University of Science and Technology, Kunming 650504, China
Energies, 2021, vol. 14, issue 18, 1-25
Abstract:
In order to ensure the safe and stable operation of a power system, the performance evaluation of transformer windings after a short-circuit test can predict whether the windings are deformed in order to provide a useful reference for the operation and maintenance of the power sector. This paper proposes a method for evaluating the performance of transformer windings in order to improve the overall effectiveness of a winding evaluation. The index data obtained based on a short-circuit impedance method, frequency response method, and oscillation wave method are used in the algorithm proposed in this paper. First, the transformer winding performance evaluation index system is constructed. Second, the weight of each index is determined by analytic hierarchy process, and then the fuzzy comprehensive assessment method is introduced, and the fuzzy evaluation matrix is established, the evaluation results are calculated using the evaluation formula. Finally, the maximum membership principle is used to determine the performance level of the transformer winding on the evaluation results, and the evaluation results of the transformer winding state are obtained. The example shows that the evaluation level of the measured transformer winding performance can be obtained by this method as “good”. Compared with the traditional method, this method can simplify the evaluation while maintaining higher accuracy.
Keywords: short-circuit test; transformer winding; performance; evaluation; analytic hierarchy process; fuzzy evaluation method (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/14/18/5832/pdf (application/pdf)
https://www.mdpi.com/1996-1073/14/18/5832/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:14:y:2021:i:18:p:5832-:d:635922
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().