EconPapers    
Economics at your fingertips  
 

Pollution Flashover Characteristics of Composite Crossarm Insulator with a Large Diameter

Jing Nan, Hua Li, Xiaodong Wan, Feng Huo and Fuchang Lin
Additional contact information
Jing Nan: State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
Hua Li: State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
Xiaodong Wan: State Key Laboratory of Power Grid Environmental Protection, China Electric Power Research Institute, Wuhan 430074, China
Feng Huo: State Key Laboratory of Power Grid Environmental Protection, China Electric Power Research Institute, Wuhan 430074, China
Fuchang Lin: State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074, China

Energies, 2021, vol. 14, issue 20, 1-12

Abstract: The composite crossarm insulator differs greatly from the suspension insulator in structure and arrangement. This study aims to determine the pollution flashover characteristics of composite crossarm insulators under different voltage grades. Four types of AC composite crossarm insulators with diameters ranging from 100 mm to 450 mm are subjected to artificial pollution test, and then the effects of the surface hydrophobicity state of silicone rubber, core diameter, umbrella structure, arrangement, and insulation distance on the pollution flashover voltage of the composite crossarm insulators are analyzed. Under the pollution grade 0.2/1.0 mg/cm 2 and voltage grade from 66 kV to 1000 kV, if the silicone rubber surface changes from HC5 to HC6, the pollution flashover voltage of the composite crossarm insulator will increase by 13.5% to 21.0% compared with the hydrophilic surface. If the core diameter changes from 100 mm to 300 mm, the pollution flashover voltage gradient decreases with the increase in core diameter; if the core diameter changes from 300 mm to 450 mm, the pollution flashover voltage gradient increases with core diameter. Under the same insulation height and core diameter, the umbrella structure will have a certain impact on pollution flashover voltage by up to 1.7% to 5.4%. Under the horizontal arrangement, the pollution flashover voltage can increase by 10.5% to 12.1% compared with that under the vertical arrangement. Under the hydrophilic surface and weak hydrophobicity state, the pollution flashover voltage has a linear relationship with the insulation distance. The above results can provide a reference for the structural design and optimization of the composite crossarm insulator.

Keywords: composite crossarm; pollution flashover characteristics; core diameter; hydrophobicity; umbrella structure; voltage gradient (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2021
References: View complete reference list from CitEc
Citations: View citations in EconPapers (4)

Downloads: (external link)
https://www.mdpi.com/1996-1073/14/20/6491/pdf (application/pdf)
https://www.mdpi.com/1996-1073/14/20/6491/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:14:y:2021:i:20:p:6491-:d:653175

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:14:y:2021:i:20:p:6491-:d:653175