Dynamics and Numerical Simulation of Contaminant Diffusion for a Non-Flushing Ecological Toilet
Zhonghua Zhang,
Lingjie Zeng,
Huixian Shi,
Gukun Yang,
Zhenjiang Yu,
Wenjun Yin,
Jun Gao,
Lina Wang,
Yalei Zhang and
Xuefei Zhou
Additional contact information
Zhonghua Zhang: National Engineering Research Center of Protected Agriculture, New Rural Development Institute of Tongji University, Shanghai 200092, China
Lingjie Zeng: State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China
Huixian Shi: National Engineering Research Center of Protected Agriculture, New Rural Development Institute of Tongji University, Shanghai 200092, China
Gukun Yang: National Engineering Research Center of Protected Agriculture, New Rural Development Institute of Tongji University, Shanghai 200092, China
Zhenjiang Yu: State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China
Wenjun Yin: State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China
Jun Gao: School of Mechanical Engineering, Tongji University, Shanghai 200092, China
Lina Wang: Shanghai Key Laboratory of Atmospheric Particle Pollution and Prevention (LAP3), Department of Environmental Science and Engineering, Fudan University, Shanghai 200433, China
Yalei Zhang: State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China
Xuefei Zhou: State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China
Energies, 2021, vol. 14, issue 22, 1-22
Abstract:
The poor indoor air quality (IAQ) of severely polluted toilets is associated with increased risk of severe disease. This study aimed to evaluate the overall IAQ according to the contaminant removal efficiency, volume average concentration, and breathing zone control level. The characteristics of contaminant transmission in a non-flushing ecological toilet (NFET) were analyzed using the computational fluid dynamics (CFD) methodology, and the proposed model was further validated based on experimental measurements. Both an orthogonal experimental design and CFD were used to analyze factors such as exhaust fan position (EFP), air change rate per hour (ACH), natural vent location (NVL), and grid height (G-h). The EFP and ACH were demonstrated to be the dominant factors affecting the IAQ, whereas NVL and G-h were found to play key roles. Single-factor analysis based on the significance levels of the ACH, EFP, and NVL was conducted using the CFD methodology to define three exhaust behaviors—namely, “ineffective”, “enhanced”, and “excessive”. These results provide key insights that may be used to improve the IAQ of NFETs.
Keywords: non-flushing ecological toilet; indoor air quality; orthogonal experiment; contaminant removal efficiency; breathing zone control level (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/14/22/7570/pdf (application/pdf)
https://www.mdpi.com/1996-1073/14/22/7570/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:14:y:2021:i:22:p:7570-:d:677853
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().