A Functional Safety Assessment Methodology for Explosion Protection with Application to a Variable Frequency Drive System
Shiguang Li and
Xiaojie Wu
Additional contact information
Shiguang Li: School of Electrical and Power Engineering, China University of Mining and Technology, 1 Daxue Road, Xuzhou 221116, China
Xiaojie Wu: School of Electrical and Power Engineering, China University of Mining and Technology, 1 Daxue Road, Xuzhou 221116, China
Energies, 2021, vol. 14, issue 23, 1-15
Abstract:
Modern explosion protection equipment, protected by traditional explosion protection technology (as defined by the international electrotechnical commission (IEC) publication IEC60079-ff series standards) and electrical/electronic/programmable electronic (E/E/PE) safety-related systems, is becoming ever more complex in coal mine development and petrochemical industry; thus, the possibility of failures in their operation is also growing. It is well-known that E/E/PE safety-related systems can be used to actively control dangerous sources, with real and expected levels of reliability, if they have been qualified according to the IEC61508-ff series standards. To uniformly evaluate the safety integrity level (SIL) of the explosion protection function of traditional explosion protection technology and E/E/PE safety-related system technology, this study analyzed the ability of these types of protection to remove the ignition risk residual, evaluating the failure rates of safety devices. The key objective of this paper is the presentation of a new equipment protection level (EPL) assessment method for explosion protection equipment based on a functional safety assessment. The method is applied to a variable frequency drive (VFD) system, and the results show that the EPL of the explosion protection equipment evaluated by this method is consistent with the EPL corresponding to the traditional explosion protection type of the IEC60079-ff series standard. Meanwhile, the flexible configuration of explosion protection safety devices and E/E/PE safety-related systems enables explosion protection equipment of different EPL levels to be designed.
Keywords: functional safety; explosion protection; failure rate; safety integrity level; explosive atmosphere; variable frequency drive (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2021
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/14/23/7872/pdf (application/pdf)
https://www.mdpi.com/1996-1073/14/23/7872/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:14:y:2021:i:23:p:7872-:d:686469
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().