EconPapers    
Economics at your fingertips  
 

Model-Based Evaluation of Air-Side Fouling in Closed-Circuit Cooling Towers

Björn Nienborg, Marc Mathieu, Alexander Schwärzler, Katharina Conzelmann and Lena Schnabel
Additional contact information
Björn Nienborg: Fraunhofer ISE—Institute for Solar Energy Systems, Division Thermal Systems and Buildings, Heidenhofstr. 2, 79110 Freiburg, Germany
Marc Mathieu: Dr. O. Hartmann GmbH & Co. KG, Uhlandstrasse 30, 71665 Vaihingen an der Enz, Germany
Alexander Schwärzler: Dr. O. Hartmann GmbH & Co. KG, Uhlandstrasse 30, 71665 Vaihingen an der Enz, Germany
Katharina Conzelmann: Dr. O. Hartmann GmbH & Co. KG, Uhlandstrasse 30, 71665 Vaihingen an der Enz, Germany
Lena Schnabel: Fraunhofer ISE—Institute for Solar Energy Systems, Division Thermal Systems and Buildings, Heidenhofstr. 2, 79110 Freiburg, Germany

Energies, 2021, vol. 14, issue 3, 1-15

Abstract: Fouling is a permanent problem in process technology and is estimated to cost 0.25% of the gross national product. Evaporative cooling systems are especially susceptible to air-side fouling: as they work with untreated outside air, they are exposed to both natural (e.g., pollen) and human-made (e.g., industrial dust) contaminants. In addition, suspended solid particles and dissolved salts in the spray water are an issue. In this study we analyzed an approach for fouling detection based on a semi-physical (grey-box) cooling tower model which we calibrated with measurement data. A test series with reliable laboratory data indicates good applicability of the model. In three datasets, the performance decreases due to fouling (scaling, which was provoked intentionally) in the range of 5–11% were clearly detected. When applied to measurement data of two cooling towers in real applications, the model also proved to be well calibratable with relatively little data (two to four operating days). For two data sets, the model yielded reasonable results when applied to long term data: a cooling tower cleaning could be retraced and nominal operation was verified during the remaining time. During the analysis of a third data set a temporary performance deviation was found, which could not be explained with the recorded data. Thus, the approach turned out to be generally applicable but requires further verification and refinement in order to increase the robustness. If successful, it can be transferred to a commercial product for need-oriented maintenance in order to reduce cooling tower operating costs and environmental impact.

Keywords: fouling; scaling; closed cooling tower; performance; heat transfer rate; fouling resistance (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/14/3/695/pdf (application/pdf)
https://www.mdpi.com/1996-1073/14/3/695/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:14:y:2021:i:3:p:695-:d:489758

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:14:y:2021:i:3:p:695-:d:489758