A Simplified Method for Modeling of Pressure Losses and Heat Transfer in Fixed-Bed Reactors with Low Tube-to-Particle Diameter Ratio
Tymoteusz Świeboda,
Renata Krzyżyńska,
Anna Bryszewska-Mazurek,
Wojciech Mazurek and
Alicja Wysocka
Additional contact information
Tymoteusz Świeboda: Faculty of Environmental Engineering, Wroclaw University of Science and Technology, 50-370 Wroclaw, Poland
Renata Krzyżyńska: Faculty of Environmental Engineering, Wroclaw University of Science and Technology, 50-370 Wroclaw, Poland
Anna Bryszewska-Mazurek: Faculty of Environmental Engineering, Wroclaw University of Science and Technology, 50-370 Wroclaw, Poland
Wojciech Mazurek: Faculty of Environmental Engineering, Wroclaw University of Science and Technology, 50-370 Wroclaw, Poland
Alicja Wysocka: Nobo Solutions S.A., 8a Stargardzka St., 54-156 Wroclaw, Poland
Energies, 2021, vol. 14, issue 3, 1-12
Abstract:
This manuscript presents a simplified method of modeling fixed-bed reactors based on the porous medium. The proposed method primarily allows the necessity of precisely mapping the internal structure of the bed—which usually is done using real object imaging techniques (like X-ray tomography) or numerical methods (like discrete element method (DEM))—to be avoided. As a result, problems with generating a good quality numerical mesh at the particles’ contact points using special techniques, such as by flattening spheres or the caps method, are also eliminated. The simplified method presented in the manuscript is based on the porous medium method. Preliminary research has shown that the porous medium method needs modifications. This is because of channeling, wall effects, and local backflows, which are substantial factors in reactors with small values of tube-to-particle-diameter ratio. The anisotropic thermal conductivity coefficient was introduced to properly reproduce heat transfer in the direction perpendicular to the general fluid flow. Since the commonly used fixed-bed reactor models validation method based on comparing the velocity and temperature profiles in the selected bed cross-section is not justified in the case of the porous medium method, an alternative method was proposed. The validation method used in this work is based on the mass-weighted average temperature increase and area-weighted average pressure drop between two control cross-section of the reactor. Thanks to the use of the described method, it is possible to obtain satisfactorily accurate results of the fixed-bed reactor model with no cumbersome mesh preparation and long-term calculations.
Keywords: fixed-bed reactor; porous media; anisotropic thermal conductivity coefficient; CFD (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://www.mdpi.com/1996-1073/14/3/784/pdf (application/pdf)
https://www.mdpi.com/1996-1073/14/3/784/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:14:y:2021:i:3:p:784-:d:491742
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().