Effects of Trapping Characteristics on Space Charge and Electric Field Distributions in HVDC Cable under Electrothermal Stress
Fuqiang Tian,
Shuting Zhang and
Chunyi Hou
Additional contact information
Fuqiang Tian: School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China
Shuting Zhang: School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China
Chunyi Hou: School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China
Energies, 2021, vol. 14, issue 5, 1-22
Abstract:
Space charge behavior has a strong impact on the long-term operation reliability of high voltage–direct current (HVDC) cables. This study intended to reveal the effect of trap density and depth on the space charge and electric field evolution behavior in HVDC cable insulation under different load currents and voltages by combined numerical bipolar charge transport (BCT) and thermal field simulation. The results show that when the load current is 1800 A (normal value), the temperature difference between the inside and the outside of the insulation is 20 °C, space charge accumulation and electric field distortion become more serious with the increase in the trap depth (E t ) from 0.80 to 1.20 eV for the trap densities (N t ) of 10 × 10 19 and 80 × 10 19 m −3 , and become more serious with the increase in N t from 10 × 10 19 to 1000 × 10 19 m −3 for E t = 0.94 eV. Simultaneously decreasing trap depth and trap density (such as E t = 0.80 eV, N t = 10 × 10 19 m −3 ) or increasing trap depth and trap density (such as E t = 1.20 eV, N t = 1000 × 10 19 m −3 ), space charge accumulation can be effectively suppressed along with capacitive electric field distribution for different load currents (1800 A, 2100 A and 2600 A) and voltages (320 kV and 592 kV). Furthermore, we can draw the conclusion that increasing bulk conduction current by simultaneously decreasing the trap depth and density or decreasing injection current from conductor by regulating the interface electric field via simultaneously increasing the trap depth and density can both effectively suppress space charge accumulations in HVDC cables. Thus, space charge and electric field can be readily regulated by the trap characteristics.
Keywords: space charge; trapping characteristics; HVDC cable; electrothermal stress; load current (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/14/5/1313/pdf (application/pdf)
https://www.mdpi.com/1996-1073/14/5/1313/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:14:y:2021:i:5:p:1313-:d:507643
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().