EconPapers    
Economics at your fingertips  
 

Comparative Study of Hysteresis Controller, Resonant Controller and Direct Torque Control of Five-Phase IM under Open-Phase Fault Operation

Mahmoud A. Mossa, Hamdi Echeikh, Ahmed A. Zaki Diab, Hassan Haes Alhelou and Pierluigi Siano
Additional contact information
Mahmoud A. Mossa: Department of Electrical Engineeing, Faculty of Engineering, Minia University, Minia 61111, Egypt
Hamdi Echeikh: Department of Electrical Engineering, National Engineering School of Monastir, Monastir 5035, Tunisia
Ahmed A. Zaki Diab: Department of Electrical Engineeing, Faculty of Engineering, Minia University, Minia 61111, Egypt
Hassan Haes Alhelou: Department of Electrical Power Engineering, Faculty of Mechanical and Electrical Engineering, Tishreen University, Lattakia 2230, Syria
Pierluigi Siano: Department of Management and Innovation Systems, University of Salerno, 84084 Salerno, Italy

Energies, 2021, vol. 14, issue 5, 1-23

Abstract: The need for regulating the operation of unhealthy motor drives has motivated the researchers to modify the control techniques in order to be valid for the new drive state. The use of a fault-tolerant facility is an attractive feature of multiphase machines; therefore, the applicability of different controllers has been established for the operation under open-phase fault conditions. The considered control algorithms were utilized to analyze the operation of the unhealthy system and evaluating the capability of the control to regulate the speed and torque under the fault condition. However, the majority of these studies considered only one control algorithm to be tested with the faulty system without comparing its performance with other techniques. The performance comparison is a vital way to visualize the features and characteristics of each algorithm. For this purpose, this paper deals with the performance comparison of the hysteresis controller, RFOC based on resonant controller and direct torque control (DTC) control under open-circuit fault conditions. A detailed comparison between the three control techniques is presented to outline the main differences between the three control procedures and identify the most appropriate technique in between.

Keywords: five-phase IM; DTC; resonant controller PR; RFOC; open phase fault operation; fault-tolerant capability (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (4)

Downloads: (external link)
https://www.mdpi.com/1996-1073/14/5/1317/pdf (application/pdf)
https://www.mdpi.com/1996-1073/14/5/1317/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:14:y:2021:i:5:p:1317-:d:507941

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:14:y:2021:i:5:p:1317-:d:507941