Analysis of the Influence of the Insulation Parameters of Medium Voltage Electrical Networks and of the Petersen Coil on the Single-Phase-to-Ground Fault Current
Dumitru Toader,
Marian Greconici,
Daniela Vesa,
Maria Vintan and
Claudiu Solea
Additional contact information
Dumitru Toader: Department Fundamental of Physics for Engineer, Politehnica University, 300006 Timisoara, Romania
Marian Greconici: Department Fundamental of Physics for Engineer, Politehnica University, 300006 Timisoara, Romania
Daniela Vesa: Department Fundamental of Physics for Engineer, Politehnica University, 300006 Timisoara, Romania
Maria Vintan: Department Computer Science and Electrical Engineering, Lucian Blaga University, 550024 Sibiu, Romania
Claudiu Solea: Department Fundamental of Physics for Engineer, Politehnica University, 300006 Timisoara, Romania
Energies, 2021, vol. 14, issue 5, 1-15
Abstract:
Settings of protection are essential to ensure the sensitivity and selectivity needed to detect defects. Making the correct settings requires the calculation of the fault currents with as little error as possible. Fault currents are influenced by the parameters of the electrical networks, including the state of the insulation and the Petersen coil, which changes during their operation electrical networks. This paper analyzes how the insulation parameters of medium voltage power lines, the parameters of the Petersen coil used to treat the neutral of the medium voltage electrical network and the value of the resistance at the fault location influence the fault current in the case of a single-phase fault. The large number of single-phase faults that occur in medium voltage electrical networks justifies this analysis. The symmetrical components method was used to calculate the fault current. The results obtained by calculation were verified experimentally by causing a single-phase-to-ground fault in a real medium voltage network. The paper presents the situations in which the analytical calculation of the single-phase-to-ground fault current can lead to inadmissibly large errors, even over 50%, but also the situations in which the errors fall below 3%.
Keywords: single-phase-to-ground fault; fault current; resonant grounded system; symmetrical components; insulation of electrical networks (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (5)
Downloads: (external link)
https://www.mdpi.com/1996-1073/14/5/1330/pdf (application/pdf)
https://www.mdpi.com/1996-1073/14/5/1330/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:14:y:2021:i:5:p:1330-:d:508206
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().