EconPapers    
Economics at your fingertips  
 

Control of Transformerless Inverter-Based Two-Stage Grid-Connected Photovoltaic System Using Adaptive-PI and Adaptive Sliding Mode Controllers

Kamran Zeb, Muhammad Saqib Nazir, Iftikhar Ahmad, Waqar Uddin and Hee-Je Kim
Additional contact information
Kamran Zeb: School of Electrical Engineering and Computer Science, National University of Sciences and Technology (NUST), Islamabad 44000, Pakistan
Muhammad Saqib Nazir: School of Electrical Engineering and Computer Science, National University of Sciences and Technology (NUST), Islamabad 44000, Pakistan
Iftikhar Ahmad: School of Electrical Engineering and Computer Science, National University of Sciences and Technology (NUST), Islamabad 44000, Pakistan
Waqar Uddin: Division of Electronics & Electrical Engineering, Dongguk University, Seoul 04620, Korea
Hee-Je Kim: School of Electrical Engineering, Pusan National University, Busan 46241, Korea

Energies, 2021, vol. 14, issue 9, 1-15

Abstract: To enhance the move towards a sustainable society, the solar Photovoltaic (PV) industry and its applications are progressing at a rapid rate. However, the associated issues need to be addressed when connecting PV to the grid. Advanced and efficient controllers are required for the DC link to control the second harmonic ripple and current controllers to inject quality active and reactive power to the grid in the grid-connected PV system. In this paper, DC-link voltage, active power, and reactive power are successfully controlled in stationary reference using Adaptive-PI (A-PI) and Adaptive-Sliding Mode Controller (A-SMC) for a 3 kW single-phase two-stage transformerless grid-connected inverter. A Resonant Harmonic Compensator (RHC)-based Proportional Resonant (PR) controller is employed in the current-controlled loop. The magnitude, phase, and frequency information of the grid voltage are provided by Second-Order General Integral (SOGI)-based PLL that has harmonic immunity, fast-tracking accuracy, and a rapid-dynamic response. MATLAB ® /Simulink ® /Simscape R2017b were used for the test bench implementation. Two scenarios were considered: in the first case, the input PV power feedforward loop was avoided, while in second case, it was included. The feedforward loop of input PV power improved the overall system dynamics. The results show that the designed controller improves both the steady-state and dynamic performance as compared with a proper-regulated PI-controller. The proposed controllers are insensitive to active and reactive power variations, and are robust, stable, faster, and fault tolerant, as compared to controllers from prior studies.

Keywords: photovoltaic system; grid-connected; adaptive-PI controller; proportional resonant controller; adaptive-sliding mode controller; phase lock loop; second-order general integral (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (2)

Downloads: (external link)
https://www.mdpi.com/1996-1073/14/9/2546/pdf (application/pdf)
https://www.mdpi.com/1996-1073/14/9/2546/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:14:y:2021:i:9:p:2546-:d:545825

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:14:y:2021:i:9:p:2546-:d:545825