Energies, 2022, vol. 15, issue 10, 1-10

Abstract: Over operation time, there are a number of internal and external factors that change the characteristics of dielectric materials that are part of the electrical equipment. In areas with high pollution, an important requirement is the acidic chemical compounds in the soil in which the power cables are laid, which penetrate the insulation by infiltration, resulting in changes in the parameters of electrical insulation and causing a decrease in operating time. The paper is focused on the analysis, through a series of experimental determinations, of the effects of stresses to which the power cables laid in acidic environments are subjected, by simulating the operating conditions in the laboratory, obtaining concrete results. It also describes the direct current test installation used in the laboratory and presents the two stages of testing the cable sample inserted in the electrolyte, the first being a stage of accelerating the degradation of the insulation by supplying higher voltages to require insulation, and the second stage being the testing in the absence of the electric field, under the direct action of the chemical compounds from the installation tank. Given that in alternating current, the electric field causes an additional heating of the dielectric due to energy losses by electric polarization, the test is performed in direct current, precisely to be able to monitor the variation of insulation resistance in relation to temperature and losses through conduction currents, as a result of the Joule–Lenz effect and not as a result of the dielectric polarization process. At the same time, the power of the direct current source used is lower compared to that of an alternative current test source and does not contribute to the generation of electrical discharges during testing.

Keywords: high-voltage testing installation; insulation resistance; electrolytic solution; induction current; insulation in acidic environment; breakdown voltage (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/15/10/3550/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/10/3550/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:10:p:3550-:d:814116

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:15:y:2022:i:10:p:3550-:d:814116