Influence of Measurement Methodologies for the Volumetric Air Flow Rate of Mobile Positive Pressure Fans on Drive Unit Performance
Piotr Kaczmarzyk,
Łukasz Warguła,
Paweł Janik and
Piotr Krawiec
Additional contact information
Piotr Kaczmarzyk: Scientific and Research Centre for Fire Protection, National Research Institute, 05-420 Józefów, Poland
Łukasz Warguła: Institute of Machine Design, Faculty of Mechanical Engineering, Poznań University of Technology, 60-965 Poznań, Poland
Paweł Janik: Scientific and Research Centre for Fire Protection, National Research Institute, 05-420 Józefów, Poland
Piotr Krawiec: Institute of Machine Design, Faculty of Mechanical Engineering, Poznań University of Technology, 60-965 Poznań, Poland
Energies, 2022, vol. 15, issue 11, 1-12
Abstract:
Since there are no legally defined testing requirements for mobile positive pressure fans, they may be tested based on methods that do not correspond to their actual operating conditions. Adequate assessment of the technical and operating conditions for this type of equipment is particularly important for equipment used in rescue operations. Such units should be characterized by efficient and reliable operation. This article investigates the influence of measurement methods of the volumetric airflow rate on the performance of a power unit. The article shows that the applied measurement method, whether it is PN-EN ISO 5801 (test conditions in a pipe duct—Method A) or other methods, i.e., ANSI/AMCA 240-15 and testing of the characteristics of the velocity profile (tests in open flow—Method B), can cause differences in the power demand of fans of from 3.2% to 4.5%. The differences in the requirements of propulsion power translate into fuel consumption and emissions of harmful exhaust gases generated by the combustion drive units (4 kW). It was also observed that fans with conventional impellers (W1) show a lower power demand when applying Method B (open flow) tests, while fans with turbo impellers (W2) show a lower power demand when Method A (duct) tests are applied. Comparative analysis of the parameters of the drive unit in the test group of fans without taking into account the measurement method can cause errors of up to about 7.7%, 6.4%, and 2.4% for the power, torque, and speed, respectively.
Keywords: PPV fan; tactical fire ventilation; fire brigade equipment; rescue equipment; non road small engine (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (2)
Downloads: (external link)
https://www.mdpi.com/1996-1073/15/11/3953/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/11/3953/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:11:p:3953-:d:825399
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().