EconPapers    
Economics at your fingertips  
 

An Appropriate Index to Assess the Global Cancellation Level of the Harmonic Currents Consumed by a Set of Single-Phase Uncontrolled Rectifiers and a Set of Fluorescent Lamps

Juan José Mesas, Luis Sainz, Lluís Monjo and Joaquín Pedra
Additional contact information
Juan José Mesas: Department of Electrical Engineering (EEBE-UPC), Universitat Politècnica de Catalunya, Av. Eduard Maristany 16, 08019 Barcelona, Spain
Luis Sainz: Department of Electrical Engineering (ETSEIB-UPC), Universitat Politècnica de Catalunya, Av. Diagonal 647, 08028 Barcelona, Spain
Lluís Monjo: Department of Electrical Engineering (EPSEVG-UPC), Universitat Politècnica de Catalunya, Av. Víctor Balaguer 1, 08800 Vilanova i la Geltrú, Spain
Joaquín Pedra: Department of Electrical Engineering (ETSEIB-UPC), Universitat Politècnica de Catalunya, Av. Diagonal 647, 08028 Barcelona, Spain

Energies, 2022, vol. 15, issue 12, 1-21

Abstract: An in-depth study of harmonic current reduction in European commercial buildings due to the harmonic cancellation effect when a set of single-phase uncontrolled rectifiers and a set of fluorescent lamps are connected at the same voltage level is essential, since both types of non-linear loads are very present in commercial and residential sectors. This paper provides an appropriate index to assess the global cancellation level of the harmonic currents for this study. The equivalent circuit per phase of the typical three-phase power system of European commercial installations is presented and simplified for the cancellation analysis of the harmonic currents consumed by a set of multiple identical single-phase uncontrolled rectifiers and a set of multiple identical fluorescent lamps connected at the same voltage level. The suitability and usefulness of the proposed index are shown by applying it to that analysis, which leads to some results of practical interest. This index can be generalized to any number of sets of multiple identical non-linear loads and can be applied in graphical and optimization studies that will allow a greater benefit from the harmonic cancellation effect to be obtained given the global nature of the index.

Keywords: commercial installation; residential installation; harmonic current; harmonic cancellation; single-phase uncontrolled rectifier; fluorescent lamp; diversity factor (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/15/12/4315/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/12/4315/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:12:p:4315-:d:837541

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:15:y:2022:i:12:p:4315-:d:837541