Early Fault Diagnosis Strategy for WT Main Bearings Based on SCADA Data and One-Class SVM
Christian Tutivén,
Yolanda Vidal,
Andres Insuasty,
Lorena Campoverde-Vilela and
Wilson Achicanoy
Additional contact information
Christian Tutivén: Escuela Superior Politécnica del Litoral (ESPOL), Faculty of Mechanical Engineering and Production Science (FIMCP), Mechatronics Engineering, Campus Gustavo Galindo, Km. 30.5 Vía Perimetral, Guayaquil EC090902, Ecuador
Yolanda Vidal: Control, Data and Artificial Intelligence (CoDAlab), Department of Mathematics, Escola d’Enginyeria de Barcelona Est (EEBE), Universitat Politècnica de Catalunya (UPC), Campus Diagonal-Besós (CDB), Eduard Maristany 16, 08019 Barcelona, Spain
Andres Insuasty: Departamento de Electrónica, Universidad de Nariño, Clle 18 Cr 50 Ciudadela Universitaria Torobajo, Pasto 52001, Colombia
Lorena Campoverde-Vilela: Escuela Superior Politécnica del Litoral (ESPOL), Faculty of Mechanical Engineering and Production Science (FIMCP), Mechatronics Engineering, Campus Gustavo Galindo, Km. 30.5 Vía Perimetral, Guayaquil EC090902, Ecuador
Wilson Achicanoy: Departamento de Electrónica, Universidad de Nariño, Clle 18 Cr 50 Ciudadela Universitaria Torobajo, Pasto 52001, Colombia
Energies, 2022, vol. 15, issue 12, 1-16
Abstract:
To reduce the levelized cost of wind energy, through the reduction in operation and maintenance costs, it is imperative that the wind turbine downtime is reduced through maintenance strategies based on condition monitoring. The standard approach toward this challenge is based on vibration monitoring, which requires the installation of specific tailored sensors that incur associated added costs. On the other hand, the life expectancy of wind parks built during the 1990s wind power boom is dwindling, and data-driven maintenance strategies issued from already accessible supervisory control and data acquisition (SCADA) data is an auspicious competitive solution because no additional sensors are required. Note that it is a major issue to provide fault diagnosis approaches built only on SCADA data, as these data were not established with the objective of being used for condition monitoring but rather for control capacities. The present study posits an early fault diagnosis strategy based exclusively on SCADA data and supports it with results on a real wind park with 18 wind turbines. The contributed methodology is an anomaly detection model based on a one-class support vector machine classifier; that is, it is a semi-supervised approach that trains a decision function that categorizes fresh data as similar or dissimilar to the training set. Therefore, only healthy (normal operation) data is required to train the model, which greatly expands the possibility of employing this methodology (because there is no need for faulty data from the past, and only normal operation SCADA data is needed). The results obtained from the real wind park show that this is a promising strategy.
Keywords: anomaly detection; condition-based maintenance; condition monitoring; fault diagnosis; main bearing; one-class support vector machine; predictive maintenance; SCADA data; wind turbine (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (2)
Downloads: (external link)
https://www.mdpi.com/1996-1073/15/12/4381/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/12/4381/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:12:p:4381-:d:840098
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().