Optimizing the Power Usage of Anti-Sweat Heaters in Glass-Door Refrigerators According to the Dew Point
Iztok Humar,
Uroš Hudomalj,
Alexander Marinšek and
Mark Umberger
Additional contact information
Iztok Humar: Faculty of Electrical Engineering, University of Ljubljana, Tržaška Cesta 25, SI-1000 Ljubljana, Slovenia
Uroš Hudomalj: Faculty of Electrical Engineering, University of Ljubljana, Tržaška Cesta 25, SI-1000 Ljubljana, Slovenia
Alexander Marinšek: Faculty of Electrical Engineering, University of Ljubljana, Tržaška Cesta 25, SI-1000 Ljubljana, Slovenia
Mark Umberger: Entia Information Technologies Development d.o.o., Dunajska Cesta 167, SI-1000 Ljubljana, Slovenia
Energies, 2022, vol. 15, issue 13, 1-12
Abstract:
Putting glass doors on the display cases of refrigerators is one of the most efficient ways to reduce the energy consumption of supermarkets. However, the glass fogs up when opening the door because of the difference in air temperature inside and outside of the refrigerator, thereby obscuring the view. To defog the glass, anti-sweat heaters (ASHs) are used. In this paper, the power usage of ASHs according to changes in the dew point (DP) inside a supermarket were evaluated for two types of ASH, i.e., the door-frame ASH and the glass ASH. The evaluation was based on measurements of the condensation on the glass doors of vertical display cases, used for the preservation of frozen foodstuffs. A mathematical model of the correlation between the ASH’s power usage and the DP was developed and used for predicting the long-term energy savings. The savings were calculated based on the measured DPs inside the supermarket, which were extrapolated over a longer time period based on their correlation with the outside DPs. Regulating the door-frame ASH according to the DP resulted in an 84.6% reduction in energy consumption and a 90.1% reduction in the case of the glass ASH, compared to the current state. The correlation between the DPs inside and outside the supermarket served as a basis for the proposed implementation of the power usage regulation of the ASH according to the DP.
Keywords: anti-sweat heaters; condensation; glass-door refrigerators; dew point; energy savings (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/15/13/4601/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/13/4601/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:13:p:4601-:d:846175
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().