Susceptibility Issues of Control Instrumentation in Electromagnetic Environment of High Current Laboratory
Jolanta Sadura,
Jan Sroka,
Przemysław Sul,
Adam Jóśko and
Maciej Owsiński
Additional contact information
Jolanta Sadura: Department of Electrical Engineering, Warsaw University of Technology, 00-662 Warsaw, Poland
Jan Sroka: Department of Electrical Engineering, Warsaw University of Technology, 00-662 Warsaw, Poland
Przemysław Sul: Department of Electrical Engineering, Warsaw University of Technology, 00-662 Warsaw, Poland
Adam Jóśko: Department of Electrical Engineering, Warsaw University of Technology, 00-662 Warsaw, Poland
Maciej Owsiński: Institute of Power Engineering, 01-330 Warsaw, Poland
Energies, 2022, vol. 15, issue 13, 1-13
Abstract:
The paper is a continuation of the research works of the authors. The aim of it is identifying the electromagnetic environment in which the control equipment of the short-circuit test stand operates. Exceptional attention was devoted to the issues related to the operation of the time-phase controller system. Measurements and identification of the electromagnetic environment were carried out on a specific short-circuit test stand, where short-circuit currents are generated by the medium-voltage (MV) short-circuit transformers. Short circuit tests are always preceded by powering the MV side of the test transformer by unloading the low-voltage (LV) side. Thereafter, the controller must wait for the release of the operator to start the test. Sometimes an electromagnetically disturbed controller starts the test without release. Such situation is undesired and can be destructive for the tested objects. Identification of the transient fields during the powering of the test transformer is indispensable for assessing the hazard of EM interference of the controller. Earlier research by the authors showed that the repetitive damped oscillating waves (DOW) are a component of the electromagnetic environment. Adequate instrumentation to cope with the problem are D-dot and B-dot field probes is needed. The paper reports such measurements along with recording the voltage signals. It was suspected that repetitive ignition and extinction of the short arc by closing the circuit breaker in the MV circuit is the origin of the DOW. Additional investigation of the circuit breaker in stand-alone operation is excluded in this hypothesis. The only possibility of the DOW is pulse traveling back and forth in the MV circuit, which is a line with distributed parameters.
Keywords: short circuit tests; time-phase controller; circuit breaker closing process; field probe; damped oscillatory waves (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/15/13/4682/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/13/4682/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:13:p:4682-:d:848255
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().