EconPapers    
Economics at your fingertips  
 

Thermal Comfort—Case Study in a Lightweight Passive House

Krzysztof Wąs, Jan Radoń and Agnieszka Sadłowska-Sałęga
Additional contact information
Krzysztof Wąs: Department of Rural Building, Faculty of Environmental Engineering, University of Agriculture in Krakow, 30-059 Krakow, Poland
Jan Radoń: Department of Rural Building, Faculty of Environmental Engineering, University of Agriculture in Krakow, 30-059 Krakow, Poland
Agnieszka Sadłowska-Sałęga: Department of Rural Building, Faculty of Environmental Engineering, University of Agriculture in Krakow, 30-059 Krakow, Poland

Energies, 2022, vol. 15, issue 13, 1-21

Abstract: Saving energy while maintaining a high-quality internal environment is an increasingly important scientific and technological challenge in the building sector. This paper presents the results from a long-term study on thermal comfort in a passive house situated in the south of Poland. The building was constructed in 2010 with the use of prefabricated, lightweight technology. The main energy source is a ground source heat pump which powers the floor heating and DHW. The building is also equipped with a mechanical ventilation system with heat recovery and a ground source heat exchanger. A lightweight building structure which has active systems with limited capabilities (especially for cooling) is a combination which increases the difficulty of maintaining a proper inner environmental condition. Extensive experimental investigations on hygrothermal performance and energy use have been carried out in the building for several years. The measurement results, such as inner air temperature and humidity, as well as the inner surface temperature of partitions, could be directly used to determine basic thermal comfort indicators, including PMV and PPD . Any missing data that has not been directly measured, such as the surface temperature of the windows, floors, and some of the other elements of the building envelope, have been calculated using WUFI ® PLUS software and validated with the available measurements. These results are not final; the full measurement of thermal comfort as an applied methodology did not consider human adaptation and assumed constant clothing insulation. Nevertheless, in general, the results show good thermal comfort conditions inside the building under research conditions. This was also confirmed via a survey of the inhabitants: 2 adults and 3 children.

Keywords: thermal comfort; lightweight passive house; hygrothermal building simulations (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/15/13/4687/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/13/4687/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:13:p:4687-:d:848375

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:15:y:2022:i:13:p:4687-:d:848375