Coordinated Control of Wind Energy Conversion System during Unsymmetrical Fault at Grid
Hemant Ahuja,
Arika Singh,
Sachin Sharma,
Gulshan Sharma and
Pitshou N. Bokoro
Additional contact information
Hemant Ahuja: Ajay Kumar Garg Engineering College, Ghaziabad 201009, Uttar Pradesh, India
Arika Singh: KIET Group of Institutions, Ghaziabad 201206, Uttar Pradesh, India
Sachin Sharma: Department of Electrical Engineering, Graphic Era Deemed to Be University, Dehradun 248002, Uttrakhand, India
Gulshan Sharma: Department of Electrical Engineering Technology, University of Johannesburg, Johannesburg 2006, South Africa
Pitshou N. Bokoro: Department of Electrical Engineering Technology, University of Johannesburg, Johannesburg 2006, South Africa
Energies, 2022, vol. 15, issue 13, 1-15
Abstract:
High penetration of wind power into the grid necessitates the coordinated action of wind energy conversion systems and the grid. A suitable generation control is required to fulfill the grid integration requirements, especially during faults. A system using a pair of voltage source converters with a squirrel cage induction generator coupled to a wind turbine is proposed to provide fault ride-through during grid faults. A threefold action is used for providing the effective fault ride-through via coordinated action of the machine side and the grid side converter. The entire wind energy conversion system is controlled such that the wind turbine remains connected even during the faults. To implement the threefold action: (i) A decoupled current controller is placed in the grid side converter, which separately controls the positive and negative sequence currents arising during faults. The grid side converter controller is capable of eliminating the double frequency oscillations at the dc-link voltage and, hence, real power, which arises during the unsymmetrical faults; (ii) Reactive power injection is additionally provided by the grid side converter for better grid support; and (iii) The vector control technique is used in machine side converter along with the droop control to adjust the generator speed and the torque resulting in actuation of the pitch control mechanism to limit power generation without shutdown of the turbine.
Keywords: induction generator; wind energy; inverters; stationary reference frame; synchronous reference frame; pitch angle; converters; grid; STATCOM (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/15/13/4898/pdf (application/pdf)
https://www.mdpi.com/1996-1073/15/13/4898/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:15:y:2022:i:13:p:4898-:d:855601
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().